LQ -40°C~-110°C
Semiconductor test chiller For non corrosive gas cooling- Potenza di riscaldamento2,5kW~25kW
- Capacità di raffreddamento0,25kW~25kW
- Gamma di potenza6,5kW~50kW
- Accuratezza media±0.3℃
- Pressione di flusso20L/min~150L/min 2,5bar
- RefrigeranteR404A/R508B
Download dei dati del prodotto
Parametri dettagliati
Modello | LQ-4015 | LQ-4030 | LQ-4060 | LQ-40100 | LQ-7515 | LQ-7530 | LQ-7560 | LQ-75100 |
LQ-4015W | LQ-4030W | LQ-4060W | LQ-40100W | LQ-7515W | LQ-7530W | LQ-7560W | LQ-75100W | |
Flusso di gas | 15m3/h | 30m3/h | 60m3/h | 100m3/h | 15m3/h | 30m3/h | 60m3/h | 100m3/h |
lowest temp. | -40℃ | -40℃ | -40℃ | -40℃ | -75℃ | -75℃ | -75℃ | -75℃ |
Area di scambio termico | 0.8m2 | 1.5m2 | 3m2 | 5m2 | 1.5m2 | 2.5m2 | 5m2 | 9m2 |
Materiale dello scambiatore di calore | Standard configuration sus304 contains a small amount of copper | |||||||
Gas inlet and outlet diameter | G3/8 | G1/2 | G1 | DN50 | G3/8 | G1/2 | G1 | DN50 |
Sistema di controllo | Programmable controller and module | |||||||
Visualizzazione e registrazione | 7-inch color touch screen, record curve temperature and alarm conditions | |||||||
compressor | France Taikang/Emerson Copeland | |||||||
Alimentazione | 220V 50HZ | 220V 50HZ | 380V 50HZ | 380V 50HZ | 220V 50HZ | 220V 50HZ | 380V 50HZ | 380V 50HZ |
1,2KW | 1,8KW | 3,5KW | 7KW | 2KW | 3KW | 6KW | 11.5KW |
Descrizione del prodotto
It is used to cool the gas (non corrosive) or recover it as non corrosive gas by condensation and liquefaction.
Pressure resistance of gas heat exchange system: 25bar; The temperature range is – 40 ℃ ~ – 75 ℃, which can meet different temperatures;
The secondary subcooling technology is adopted, with rapid refrigeration and low refrigeration temperature;
Semi closed piston compressor, scroll flexible compressor and fully closed piston compressor of imported brands are adopted;
The evaporator adopts casing heat exchanger, which has the advantages of small volume, long residence time and high efficiency;
Danfoss expansion valve and Emerson electronic expansion valve are adopted, with high temperature control accuracy;
Siemens plcs7-200 / 300 and lneya touch screen display are used for automatic control operation;
The whole machine is installed. The system has been tested in the factory. Users only need to install the refrigerant pipeline and cooling water pipeline to run;
Factory test: each refrigeration unit shall be tested with load in the factory for no less than 12 hours;
![Send us a message about LQ series](https://www.lneya.com/wp-content/uploads/2023/05/LQ.jpg)
Potreste essere interessati anche a questi prodotti
MD -75℃~225℃
Quick temperature change control chuckConfiguration DetailsProduct Description -75℃ to 225°C Model MD-708 MD-712 MDL-708 Temp. Range -75℃~225℃ -75℃~225℃ -75℃~225℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ temperature…
YQH 0℃~-75℃
Precisione della temperatura ±0.1℃ Controllo del flusso 12~45/min
FLT-100℃~80℃ a bassa temperatura in cascata
Precisione della temperatura ±0.1℃ Controllo del flusso 12~45/min
FLTZ -30℃~40℃ Serie a doppia conversione di frequenza
Precisione della temperatura ±0.1℃ Controllo del flusso 15~45/min 6bar max Gamma di potenza 380V 3,5kW