FREDDI
Industrial Process Chiller System replaces cooling tower; Supports both indoor and outdoor options.
TEMPERATURE RANGE -100℃~135℃

Ricerca nell'intera stazione
Te)mperature control range: -80 ℃ to +30 ℃
Applicazioni: Use for industrial, labortory reation & testing etc.
LT series | 10℃~30℃ | -25℃~30℃ | -45℃~30℃ | -60℃~-30℃ | -80℃~-40℃ |
Capacità di raffreddamento | 3KW~14KW | 1.5KW~5KW | 1.6KW~4.8KW | 0.7KW~4.8KW | 0.4KW~2.5KW |
Controllo del flusso | 30L/min~50L/min | ||||
Refrigerante | R-134A / R407C | R-404A / R507C | R-404A / R507C | R-404A/R23 | R-404A/R23 |
Precisione del controllo della temperatura | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ |
Capacità di raffreddamento -15℃ |
3KW~14KW@15℃ | 1.5kw~5kw@-15℃ | 0.7kw~2.5kw@-35℃ | 1.3kw~4.8kw@-40℃ | 0.7kw~2.5kw@-60℃ |
Temperature control range: -115 ℃ to 90 ℃;Temperature Accuracy Is ± 0.5 ℃
Applicazioni: vari reattori, sistemi di distillazione o estrazione, laboratori, istituti di ricerca, industrie chimiche, farmaceutiche, petrolchimiche, biochimiche, mediche, ospedaliere, laboratori di ricerca e sviluppo, test sui semiconduttori, aerospaziali, biologiche e altre industrie.
LTZ series | -40℃~90℃ | 5℃~30℃ | -25℃~30℃ | -45℃~20℃ | -60℃~-30℃ | -80℃~-50℃ | -115℃~-80℃ |
Capacità di raffreddamento | 0.7KW~11.5KW | 23KW~300KW | 7KW~117.5KW | 2.85KW~61.56KW | 4.9KW~93.2KW | 3.7KW~78.5KW | 0.6KW~2.8KW |
Potenza di riscaldamento | 2.5kW~10KW | ||||||
Precisione del controllo della temperatura | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ |
Pompa di circolazione Flow MAX |
30L/min 1,6bar |
Temperature control range: 2℃~20℃; Temperature control accuracy ±0.5℃
Suitable for the production process of 2°℃~5°C DI water demand. Normal temperature Dl water enters the temperature control unit, and the target temperature D1 water is output, which solves the problem of easy freezing of water within 5°C.
Intervallo di temperatura | LTZ 2℃~+20℃ |
Cooling Capacity@3℃ | 5KW~25KW |
Precisione del controllo della temperatura | ±0.5℃ |
★ | The models are both air-cooled and water-cooled. Widely used, welcome to consult and customize. |
Temperature control range: -11 ℃ to 5 ℃
Chilled water:outlet water temperature 7℃, return water temperature 12℃; condensing temperature 40℃.
Intervallo di temperatura | LTG -25℃~5℃ | LTG -45℃~-10℃ | LTG -60℃~-10℃ | LTG -80℃~-30℃ | LTG -115℃~-50℃ |
Capacità di raffreddamento | 111KW~318KW | 70KW~180KW | 87KW~238KW | 48KW~131KW | 48KW~131KW |
Refrigeration Power | 74KW~205KW | 48KW~113KW | 94KW~260KW | 76KW~213KW | 76KW~213KW |
Refrigerante | R404A | R404A | R404A | R404A | R404A |
★ | The models are both air-cooled and water-cooled. Widely used, welcome to consult and customize. |
Temperature control range: -65 ℃ to 25 ℃
Suitable for temperature control applications such as microchannelreactors, plate heat exchangers, cold plates, heat sink plates, andtubular reactors with small heat exchange areas, large refrigerationcapacities, and small temperature differences;
Serie ZLTZ |
3 3W |
6 6W |
10 10W |
3-3 3-3W |
3-6 3-6W |
3-10 3-10W |
6-3 6-3W |
6-6 6-6W |
6-10 6-10W |
Intervallo di temperatura | -10 ℃~+25℃ | -10℃~+25℃ | -10℃~+25℃ | -30 ℃~+25℃ | -30℃~+25℃ | -30℃~+25℃ | -65 ℃~-30℃ | -65℃~-30℃ | -65℃~-30℃ |
Precisione del controllo della temperatura | ±0.3℃ | ||||||||
Cooling capacity 50HZ | @0℃ 5kW | @0℃ 10kW | @0℃ 16kW | @-20℃ 3kW | @-20℃ 6.5kW | @-20℃ 11kW | @-50℃ 2.6kW | @-50℃ 5kW | @-50℃ 8kW |
Temperature control range: -40 ℃ to 100 ℃
Chilled water:outlet water temperature 7℃, return water temperature 12℃; condensing temperature 40℃.
Modello | Serie di conversione di frequenza FLTZ | Multi-channel Series | Heat Exchange Series ETCU |
Intervallo di temperatura | -45℃~+90℃ | -45℃~+100℃ | 5℃~+90℃ |
Capacità di raffreddamento | 1KW~40KW | 2KW~6KW | 5KW~300W |
Precisione del controllo della temperatura | ±0.05℃ | ±0.05℃ | ±0.05℃ |
Flusso di acqua di raffreddamento @20℃ | 1.5m³/h~9m³/h | 1.2m³/H~10.2m³/H | 1.5m³/H~8m³/H |
★ | The models are both air-cooled and water-cooled. Widely used, welcome to consult and customize. |
Temperature control range: -40 ℃ to 100 ℃
We supply our customers in the automotive industry with high-performance devices. They not only dynamically cover the entire temperature range from -40°C to +160°C and the rapid temperature changes required on test benches.
Serie KRY | -20℃~+100℃ | -40℃~+100℃ | -20℃~+100℃ 6S | -40℃~+100℃ 6S | -40℃~+100℃ 2T | 0℃~+100℃ | 0℃~+100℃ 6S | -40℃~+100℃ 2T |
Precisione del controllo della temperatura | ±0.3℃ | |||||||
Precisione della portata | ±0,2 L/min | |||||||
Heating capacity | 5.5KW~38KW | 5.5KW~60KW | 15KW~38KW | 15KW~38KW | 7.5KW*2~38KW*2 | 2.5KW~38KW | 15KW~38KW | 2.5KW*2~38KW*2 |
Capacità di raffreddamento | 2.8KW~38KW | 1.2KW~60KW | 10KW~60KW | 5KW~60KW | 1.8KW*2~60KW*2 | 1.8KW~60KW | 18KW~60KW | 1.8KW*2~60KW*2 |
Potenza 380V50HZ | 11KW~45KW | 10KW~84KW | 36KW~75KW | 38KW~82KW | 28KW~158KW | 4.5KW~61KW | 38KW~82KW | 9KW~120KW |
If you haven’t found a suitable model yet, please try contacting us for assistance.
Wechat 18914253067
Whatsapp 8618914253067
> Why should you choose us for your custom chillers Manufacturing?
We offer:
Experience you can count on—
We’ve been designing and building custom chillers for more than 20 years. From medical chillers to energy storage chillers and everything in between, we’ve built chillers for virtually every industry and every application.
Same day quotes—
Get a quote for your project today! We often provide custom quotes in as little as 30 minutes.
24/7 customer service—
We are always here for you. Whether you have a question or need a quote, there’s always somebody here to communicate with you 24/7.
Durable, reliable equipment—
Our products are built with premium-grade materials, and we offer competitive warranties on all custom chillers.
We specializes in custom chiller products. We have our liquid chiller system designs in everything from Semiconductor process equipment, FCEV Hydrogen Refeuling Stations and Bio-Pharmaceutical OEM process control systems. LNEYA can design any shape to fit around your equipment, pump selections to meet all your needs, air-cooled, water-cooled, multiple cooling loops. Special interface requirements, digital or analog, pump output heat transfer fluid flow and pressure control, temperature cycling and ramping all available.
Contact us today and learn more about our abilities in manufacturing custom chillers. Our staff welcomes any application challenges concerning your custom chillers.
contattateci
Inviateci la vostra richiesta e vi contatteremo entro 24 ore.