FLT -100℃~90℃
semiconductor production process water chiller
- Precisione della temperatura±0.1℃
- Controllo del flusso12~45/min
- TipoFrequency Variable Series
- Gamma di potenza380V


FLTZ -100℃~+90℃ Low Temperature Cascade Refrigeration Series
Modello | FLTZ-002 | FLTZ-003 | FLTZ-004 | FLTZ-006 | FLTZ-008 | FLTZ-010 | FLTZ-015 |
FLTZ-002W | FLTZ-003W | FLTZ-004W | FLTZ-006W | FLTZ-008W | FLTZ-010W | FLTZ-015W | |
Intervallo di temperatura | 5℃~90℃ | ||||||
Precisione del controllo della temperatura | ±0,05℃(Temperatura di uscita a stato stazionario) | ||||||
Cooling capacity @10℃ | 6kW | 8kW | 10kW | 15kW | 20kW | 25kW | 40kW |
Internal circulating fluid volume | 4L | 5L | 6L | 8L | 10L | 12L | 20L |
Volume del vaso di espansione | 10L | 10L | 15L | 15L | 20L | 25L | 35L |
Refrigerante | R410A | ||||||
Refrigerating medium | Silicone oil, fluorinated liquid, polyol aqueous solution, DI, etc. (DI temp needs to be controlled above 10 ℃) | ||||||
Dimensioni del collegamento | ZG1/2 | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 |
Cooling water connection size | ZG1/2 | ZG1/2 | ZG3/4 | ZG1 | ZG1 | ZG1 | ZG1 1/8 |
Flusso di acqua di raffreddamento @20℃ | 1,5 m³/h | 2m³/h | 2,5 m³/h | 4m³/h | 4,5 m³/h | 5,6 m³/h | 9m³/h |
Process temperature control | The remote target temperature can be controlled by combining the self created model free self built tree algorithm and cascade algorithm |
||||||
Dimensioni cm | 950*380*1055 | 950*380*1055 | 950*380*1055 | 980*430*1400 | 980*430*1400 | 1080*600*1500 | 1080*600*1500 |
Modello | FLTZ-1002W | FLTZ-1004W |
Intervallo di temperatura | -100℃~+90℃ | |
Precisione del controllo della temperatura | ±0,05℃(Temperatura di uscita a stato stazionario) | |
Controllo del flusso | 7~25L/min | 12~45L/min |
Cooling capacityat-90℃ | 1,5kW | 3kW |
Capacità di riscaldamento | 3,5kW | 5,5kW |
Internal circulating fluid volume | 5L | 8L |
Volume del vaso di espansione | 10L | 15L |
Heat-conduction medium | Liquido fluorurato | |
Dimensioni del collegamento | ZG3/4 | ZG3/4 |
Cooling water connection size | ZG3/4 | ZG1 |
Cooling water@20℃ | 50L/min 2bar~7bar | 100L/min 2bar~7bar |
Circuit breaker | 32A | 63A |
Process temperature control | The remote target temperature can be controlled by combining the self created model free self built tree algorithm and cascade algorithm |
FLTZ -45℃~90℃
Modello | FLTZ-002 | FLTZ-003 | FLTZ-004 | FLTZ-006 | FLTZ-008 | FLTZ-010 | FLTZ-015 |
FLTZ-002W | FLTZ-003W | FLTZ-004W | FLTZ-006W | FLTZ-008W | FLTZ-010W | FLTZ-015W | |
Intervallo di temperatura | 5℃~90℃ | ||||||
Precisione del controllo della temperatura | ±0,05℃(Temperatura di uscita a stato stazionario) | ||||||
Cooling capacity @10℃ | 6kW | 8kW | 10kW | 15kW | 20kW | 25kW | 40kW |
Internal circulating fluid volume | 4L | 5L | 6L | 8L | 10L | 12L | 20L |
Volume del vaso di espansione | 10L | 10L | 15L | 15L | 20L | 25L | 35L |
Refrigerante | R410A | ||||||
Refrigerating medium | Silicone oil, fluorinated liquid, polyol aqueous solution, DI, etc. (DI temp needs to be controlled above 10 ℃) | ||||||
Dimensioni del collegamento | ZG1/2 | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 |
Cooling water connection size | ZG1/2 | ZG1/2 | ZG3/4 | ZG1 | ZG1 | ZG1 | ZG1 1/8 |
Flusso di acqua di raffreddamento @20℃ | 1,5 m³/h | 2m³/h | 2,5 m³/h | 4m³/h | 4,5 m³/h | 5,6 m³/h | 9m³/h |
Process temperature control | The remote target temperature can be controlled by combining the self created model free self built tree algorithm and cascade algorithm |
||||||
Dimensioni cm | 950*380*1055 | 950*380*1055 | 950*380*1055 | 980*430*1400 | 980*430*1400 | 1080*600*1500 | 1080*600*1500 |
Modello | FLTZ-202 | FLTZ-203 | FLTZ-204 | FLTZ-206 | FLTZ-208 | FLTZ-210 | FLTZ-215 |
FLTZ-202W | FLTZ-203W | FLTZ-204W | FLTZ-206W | FLTZ-208W | FLTZ-210W | FLTZ-215W | |
Intervallo di temperatura | -25℃~90℃ | ||||||
Precisione del controllo della temperatura | ±0,05℃(Temperatura di uscita a stato stazionario) | ||||||
Controllo del flusso | 10~25L/min | 15~45L/min | 25~75L/min | ||||
Cooling capacity @-15℃ | 2kW | 3kW | 3,8kW | 6kW | 7.6kW | 10kW | 15kW |
Internal circulating fluid volume | 4L | 5L | 6L | 8L | 10L | 12L | 20L |
Volume del vaso di espansione | 10L | 10L | 15L | 15L | 20L | 25L | 35L |
Refrigerante | R404A | ||||||
Refrigerating medium | Silicone oil, fluorinated liquid, glycol solution etc | ||||||
Dimensioni del collegamento | ZG1/2 | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 |
Cooling water connection size | ZG1/2 | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 1/8 |
Flusso di acqua di raffreddamento @20℃ | 1,2 m³/H | 1,6 m³/H | 2,6 m³/H | 3,6 m³/H | 5,5 m³/H | 7m³/H | 10,2 m³/H |
Process temperature control | The remote target temperature can be controlled by combining the self created model free self built tree algorithm and cascade algorithm |
||||||
Dimensioni cm | 950*380*1055 | 950*380*1055 | 950*380*1055 | 980*430*1400 | 980*430*1400 | 1080*600*1500 | 1080*600*1500 |
Modello | FLTZ-402 | FLTZ-403 | FLTZ-404 | FLTZ-406 | FLTZ-408 | FLTZ-410 | FLTZ-415 |
FLTZ-402W | FLTZ-403W | FLTZ-404W | FLTZ-406W | FLTZ-408W | FLTZ-410W | FLTZ-415W | |
Intervallo di temperatura | -45℃~90℃ | ||||||
Precisione del controllo della temperatura | ±0,05℃(Temperatura di uscita a stato stazionario) | ||||||
Controllo del flusso | 10~25L/min 5bar max | 15~45L/min 5bar max | 25~75L/min 5bar max | ||||
Riscaldamento | Using compressor heating, prevent condenser frosting technology | ||||||
Cooling capacity @-35℃ | 1kW | 1,4 kW | 1,8kW | 2,5kW | 3,3 kW | 5kW | 8kW |
Internal circulating fluid volume | 4L | 5L | 6L | 8L | 10L | 12L | 20L |
Volume del vaso di espansione | 10L | 10L | 15L | 15L | 20L | 25L | 35L |
Refrigerante | R404A | ||||||
Refrigerating medium | Silicone oil, fluorinated liquid, glycol solution etc | ||||||
Dimensioni del collegamento | ZG1/2 | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 |
Cooling water connection size | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | ZG1 1/8 |
Flusso di acqua di raffreddamento @20℃ | 1,5m³/H | 2,4 m³/H | 3,5 m³/H | 5m³/H | 5,5 m³/H | 6m³/H | 8m³/H |
Process temperature control | The remote target temperature can be controlled by combining the self created model free self built tree algorithm and cascade algorithm |
||||||
Dimensioni cm | 950*380*1055 | 950*380*1055 | 950*380*1055 | 980*430*1400 | 980*430*1400 | 1080*500*1500 | 1080*500*1500 |
Heat exchange Chiller Compressor-free
Modello | ETCU-005W | ETCU-015W | ETCU-030W | ETCU-050W | ETCU-100W | ETCU-200W | ETCU-300W |
Intervallo di temperatura | Cooling water temperature +5℃~90℃ | ||||||
Precisione del controllo della temperatura | ±0,05℃(Temperatura di uscita a stato stazionario) | ||||||
Temperatura dell'acqua di raffreddamento | 7℃~30℃ Cooling water flow is controlled by Siemens/Honeywell regulating valves | ||||||
Capacità di raffreddamento | 5kW | 15kW | 30kW | 50kW | 100kW | 200kW | 300kW |
Test conditions: When the maximum circulation amount, the temperature difference between the temperature control temperature and the cooling water temperature is 15℃ |
|||||||
Pompa di circolazione | 7~20L/min 5bar | 15~40L/min 5bar | 20~60L/min 5bar | 40~110L/min 5bar | 150~250L/min 5bar | 250~500L/min 5bar | 400~650L/min 5bar |
Volume del serbatoio | 5L | 10L | 20L | 30L | 60L | 120L | 240L |
Dimensioni cm | 480*750*390 | 480*750*390 | 480*750*500 | Customization | Customization | Customization | Customization |



refrigeratori che controllano la temperatura di lavorazione sulle apparecchiature Fab

Raffreddatore a canale singolo raffreddato ad aria, progettato principalmente per le macchine di incisione. Viene utilizzato per fornire un controllo indipendente della temperatura delle pareti laterali della camera.
Applicazioni

Inviateci la vostra richiesta e vi contatteremo entro 24 ore.
consigliare i prodotti
FLTZ -45℃~90℃
Metodo di riscaldamento entro 40 ℃ adotta un compressore di riscaldamento a gas caldo completamente chiuso, e la macchina funziona ininterrottamente per 24 ore Il dispositivo di controllo della temperatura dei semiconduttori Chiller è utilizzato principalmente per...
caricamento...
已经是到最后一篇内容了!