LNEYA data center liquid cooling solutionLiquid Cooled CDU Distribution Unit
Cold plate liquid cooling CDU-15kW
LNEYA relies on its strong R&D, construction, and operation and maintenance capabilities in the field of data centers to launch a cold-plate liquid-cooled CDU with a new air-liquid architecture. Building construction and renovation of old machine rooms, with excellent PUE indicators throughout the year, green, energy-saving, safe and reliable operation.

Applications: Renovation of small and medium-sized old data center
Energy saving, high efficiency and superior performance
Air-liquid structure, heat dissipation up to 12KW, green and energy-saving, system PUE≤1.2
Standard plug-in design, flexible layout, height is only 5U. Improve the rate of cabinets in the computer room
Front, side inlet, rear outlet air duct design, optimized airflow organization, cold and hot aisle isolation
Easy to install and easy to maintain
Does not involve the primary side pipeline layout, reducing the risk of pipeline laying, engineering quantity and water entering the machine room
Modular design, highly integrated products, easy installation, easy maintenance interface, standard quick connection, two-way cut-off of the flow channel, direct plug-in and maintenance of the pipeline on site
Renovation is simple. The old computer room can rely on the existing refrigeration system, only
Intelligent optimization of remote operation
System status analysis, real-time regulation of refrigerant flow, flow velocity and air volume, load balancing
Liquid product touch screen on-site and host computer remote centralized monitoring, human-computer interaction
Friendly interface
Anti-condensation control, liquid leakage detection, enhanced anti-interference design, high stability Support Modbus-RTUTCPMP communication
Safe and reliable system stability
Double-pump 2N redundant frequency conversion design, automatic switching in case of failure; when the two pumps are running at the same time, overclocking can increase the heat transfer by about 10%
Low-noise dual-fan design, when a single fan fails, the entire liquid cooling system will not stop
Expansion tank for pressure stabilization, full-scale group system design, leakage concealment reduction
High-efficiency pure copper micro-channel heat exchanger, highly compatible with pure steel liquid cold plate, improving system reliability
Introduction to cold plate liquid cooling system products and equipment
Introduction to cold plate liquid cooling chiller
caricamento...
已经是到最后一篇内容了!
Forniamo consulenze gratuite e soluzioni complete 7*24


E-mail: sales@cnzlj.com
WhatsApp: 086 13912479193
Raccomandazioni correlate
-
Introduction to cold plate liquid cooling system products and equipment
1087Introduction to cold plate liquid cooling chiller
Visualizza i dettagli -
Immersion phase change liquid cooling system
1109What is immersion phase change liquid cooling system?
Visualizza i dettagli -
Failure Analysis of Ultra Low Temperature Chiller Supporting Distillation Equipment
1306Once the freezer used in the matching distillation equipment fails, we need to solve it in a timely and effective manner to avoid affecting the operation of the entire experiment. In the pharmaceutical, chemical and other industries, low temperatu...
Visualizza i dettagli -
Quali sono gli interventi di manutenzione dei refrigeratori a glicole nel funzionamento quotidiano?
1177Nel funzionamento quotidiano del refrigeratore di glicole, se non viene effettuata la manutenzione, l'effetto di raffreddamento sarà ridotto. Pertanto, per migliorare l'efficienza operativa, si consiglia di eseguire la necessaria manutenzione quotidiana. Refrigeratore...
Visualizza i dettagli -
Description of LNEYA industrial ultra-low temperature freezer
1234LNEYA industrial ultra-low temperature freezer is mainly used in industrial cold treatment to precipitate uniform, fine and dispersed carbides on the metal structure matrix. The appearance of such a carbide will bring about a significant increase ...
Visualizza i dettagli -
Instructions for using the hydrogenation reactor cooling and heating integrated system
1176There are many accessories in the hydrogenation reactor cooling and heating integrated system, from the compressor to the electrical components. LNEYA reminds you that if you find more evaporator freezing oil, it is recommended to deal with it in ...
Visualizza i dettagli
Invia per la consultazione
Vi risponderemo entro 24 ore