Ricerca nell'intera stazione

Themal Test System

AET -75℃~250℃

Gas outlet temperature
± 0.1 ℃
Air handing 22m³/h~95m³/h
Remote process temperature precision ± 0.5 ℃
Pressure 4bar~8bar
AET series

-75°C

lowest

-250°C

Highest

±0.1°C

Precisione del controllo della temperatura


Modalità AET-4025
AET-4025C
AET-4050
AET-4050C
AET-4095W
AET-4095WC
AET-7025
AET-7025C
AET-7050W
AET-7050WC
AET-7095W
AET-7095WC
Intervallo di temperatura  -40℃~250℃  -75℃~250℃
Precisione della temperatura Temperatura di uscita del gas ± 0,1 ℃, precisione della temperatura di processo remota ± 0,5 ℃
Temperatura del gas opzionale per la creazione della bocca e temperatura target di processo
Requisiti dell'aria Filtro aria < 5um, contenuto di olio nell'aria < 0,1um, temperatura e umidità dell'aria: 5 ℃ -32 ℃ 0-50% Pressione RH 4bar~8bar
Manipolazione dell'aria 22m³/h 50m³/h 95m³/h 22m³/h 50m³/h 95m³/h
Controllo della temperatura di processo La temperatura del bersaglio remoto può essere controllata combinando il modello autocostruito con l'albero libero autocostruito.
algoritmo e algoritmo a cascata
Dimensioni cm 43*46*112 52*57*132 60*63*160 54*69*112 65*85*132 75*95*160

Il sistema di refrigerazione adotta la valvola di espansione elettronica per controllare con precisione la capacità di raffreddamento..


Touch screen a colori da 7 pollici, visualizzazione della temperatura del gas, della pressione, della portata, della pressione e della temperatura del sistema di refrigerazione.


The suffix W represents water cooling
Il suffisso c rappresenta il riciclo del gas
.



LNEYA never disappoints users!

Advantages of Thermal Test System

LNEYA never disappoints users!

Details of thermal Test system

Gas outlet temperature control accuracy is around 0.1℃

Temperature control accuracy in long-distance processes is around 0.5℃

LQ -110℃~-40℃
Nitrogen chillers

Gas flow 15m³/h~100m³/h
Circuit breaker 10A~25A
Lowest temperature -40℃/-75℃/-110℃

AES -120℃~225℃
Temperature forcing system

Temperature accuracy ±0.1℃
Air treatment capacity 10m³/h-30m³/h 5bar-7.6bar
Heating and cooling rate <10s

AET -75℃~250℃
Thermal test system

Temp range Gas outlet ± 0.1℃, remote process ± 0.5℃
Air handing 22m³/h~95m³/h
Heating and cooling rate <10s

AI -105℃~125℃
Air circulation chiller

Heating power 3.5KW
Cooling capacity 1KW~3.5KW
Temp accuracy ±0.05℃

DR series -7℃
Industrial gas dryer

Pressure range 0.65~1.0Mpa
Dew point temperature -70℃
Gas processing capacity 425L/Min~1750L/Min

You can trust our portable chiller factory

We are a very powerful chiller supplier with our own factory and more than 20 years of experience in the field of temperature control

Global service

Served more than 30,000 customers.
Exported to more than 20 countries.

Certification patents

Has obtained CE certification, SGS certification, ISO certification.

After-sales service

Provide comprehensive technical training.
With 24/7 solutions.

Professional team

Founded in 2010, with 15 years of industry experience.
20% of employees are technicians.

Quality control

Visual inspection.
Performance test.
Electrical safety test.

Thermal shock testing simulates a products life cycle by exposing the product to rapid changes of temperatures ranging from -60°C to 170°C. This is completed by using a dual climate chamber that will transfer the product from one temperature extreme to the other, in less than 30 seconds.

*
*
Invio....
Inviato con successo!
Invio fallito! Riprovare più tardi
Errore e-mail!
Errore telefonico!