Immersion phase change liquid cooling system
A large amount of data throughput and calculation makes the data center, which is the “brain” of emerging technologies such as artificial intelligence and big data, face unprecedented challenges in energy consumption and heat dissipation. Liquid cooling technology and liquid cooling data centers for equipment such as liquid cooling servers have emerged as the times require.
In the working state, each heating component will generate heat, causing the coolant to heat up. When the temperature of the cooling liquid rises to the boiling point corresponding to the system pressure, the cooling liquid undergoes a phase change, changing from a liquid state to a gaseous state, and absorbs heat through the heat of vaporization to realize heat transfer, which is the most energy-saving and efficient refrigeration in liquid cooling model.
Immersion cooling medium (such as fluorinated liquid), special cooling liquid has high insulation, low viscosity, non-flammable characteristics, and can ensure chemical inertness and stability within the operating range. However, due to the price and loss of fluorinated liquid media, the overall operating cost is high. Our LNEYA liquid-liquid circulation distribution cooling system was born specifically for this situation, which greatly reduces the loss of fluorinated liquid.
The core components of the cold plate liquid-cooled server effectively reduce the PUE of the data center.
Among the eight major nodes of the computing hub in the future, the PUE of large and above data centers in East China and large and above data centers in western regions with a favorable climate should drop below 1.25. Due to its obvious advantages, liquid cooling has become the main cooling technology for data centers. Among them, the cold plate liquid cooling technology is mature and ecologically perfect. As the core component of the cold plate liquid cooling server, the cold plate also plays an important role in effectively reducing the PUE of the data center.
Liquid-cooled data centers should take comprehensive reliability measures at all levels of servers, cabinets and micro-modules. LNEYA cold plate liquid cooling modular data center solution takes a single module as a unit, integrates IT cabinets, power distribution units, closed components, refrigeration units, wiring and other functionally independent units to realize the complete functions of the data center. It can be flexibly disassembled and transported, which not only saves the space of the computer room but also expands the class, and realizes rapid deployment in batches.
Forniamo consulenze gratuite e soluzioni complete 7*24


E-mail: sales@cnzlj.com
WhatsApp: 086 13912479193
Raccomandazioni correlate
-
LNEYA data center liquid cooling solution Liquid Cooled CDU Distribution Unit
1316LNEYA data center liquid cooling chiller CDU
Visualizza i dettagli -
Introduction to cold plate liquid cooling system products and equipment
1084Introduction to cold plate liquid cooling chiller
Visualizza i dettagli -
Chemical synthesis process control system temperature control system TCU
1100Today, let's talk about our DCS integrated control system (temperature and other control of synthetic process). Scalability: the system is an open system, which provides standard TCP / P data communication interface protocol, interface software an...
Visualizza i dettagli -
Operation method of reaction kettle for circulating heating device
1066The laboratory single-layer glass reactor equipped with the circulating heating device can place a flask containing the reaction solvent on the inner layer for stirring reaction, and the interlayer can realize constant temperature heating and cons...
Visualizza i dettagli -
Cooling simulation system for battery pack extreme performance test
1121With the development of technology, pure electric vehicles are becoming more and more common, but pure electric vehicles are difficult to get a better solution in terms of cruising range, charging speed, and pollution after battery waste. This mak...
Visualizza i dettagli -
TCU temperature control model selection and technical parameter description
1260TCU temperature control is also a two-cycle unit single-fluid temperature control system. When selecting the model, it is very important for the whole temperature control reaction. Only the appropriate reaction system is used to exotherm and absor...
Visualizza i dettagli
Invia per la consultazione
Vi risponderemo entro 24 ore