Come risolvere il problema dell'insufficiente capacità di raffreddamento del sistema del ciclo di raffreddamento dei semiconduttori?
Il sistema del ciclo di raffreddamento dei semiconduttori è un dispositivo per il raffreddamento della parte di riscaldamento dei semiconduttori. LushiA ricorda che se la capacità di raffreddamento è insufficiente durante il funzionamento, è necessario controllare in tempo se qualcosa è andato storto. W...
When the cooling capacity of the semiconductor cooling cycle system is insufficient, it is first determined whether the filter is blocked. The blockage of the filter includes: suction filter blockage and dry filter blockage. At this time, it only needs to be cleaned and cleaned.
By observing whether it is the reason why the expansion valve of the semiconductor cooling circulation system is too small or too large, the amount of water is adjusted. The problem of leakage of the filling agent in the temperature sensor of the expansion valve can be solved by opening the cooling tower. A dirty or blocked ice valve can be solved by cleaning.
In the semiconductor cooling cycle system, the bearing clearance after the bearing wear is too large, and the problem of insufficient cooling capacity can be solved by inspection and replacement. Use components with precise structure, high reliability and long life. To ensure the stable operation of the unit. The condenser is a shell-and-tube condenser that optimizes temperature field distribution and refrigerant flow field distribution, and has high heat exchange efficiency. The outer fin design of the heat exchange tube enhances the heat exchange condensation and improves the heat exchange efficiency outside the tube.
Insufficient refrigerant charging in the semiconductor cooling cycle system, excessive refrigerant leakage, etc. may also cause insufficient cooling capacity of the semiconductor cooling cycle system. These problems can be achieved by adding or subtracting refrigerant recharge amount, leak detection, and adding refrigerant after maintenance. solve. The evaporator is used with too small evaporator to thicken the frost>There is a large amount of lubricating oil in the evaporator or the outlet valve of the liquid reservoir is too small, the cooling water is insufficient or the water temperature is too high, so the semiconductor cooling circulation system will be cooled. Not enough. If the evaporator is too small, it can reduce the heat load or replace the evaporator. If the evaporator frost is too thick, it needs to be frosted regularly. There is a lot of lubricating oil in the evaporator, and the refrigeration oil, condenser or reservoir is recovered. The outlet valve is opened too small, and the outlet valve is properly opened.
In addition, there is excess air in the refrigeration system of the semiconductor cooling cycle system, and the energy adjustment indication is incorrect and needs attention. Excess air in the refrigeration system can be solved by discharging air. If the energy adjustment indication is incorrect, the indicator light may be broken and can be solved by inspection and replacement.
The reason for the insufficient cooling capacity in the semiconductor cooling cycle system is as shown above. It is recommended that users find out that they can contact the manufacturer in time for after-sales solution.

Raccomandazioni correlate
-
Operation LNEYA high and low temperature cycle machine note
1105LNEYA high and low temperature cycle machine uses mechanical refrigeration to obtain low temperature heating tube heating to obtain high temperature. It is used with various glass reactors and reactors. What should be paid attention to when using ...
Visualizza i dettagli -
Diverse considerazioni importanti per le imprese quando si utilizzano i raffreddatori per riscaldamento
1224Oltre a quanto sopra indicato, le imprese devono prevedere una persona responsabile dell'avvio e dell'arresto dei frigoriferi, degli interruttori, delle riparazioni e della manutenzione. Le precauzioni per l'uso dei frigoriferi nelle aziende sono...
Visualizza i dettagli -
How to choose organic waste gas for condensation treatment?
1234Condensation treatment of organic waste gas equipment is currently used in the environment of environmental protection requirements, then how to choose the organic waste gas equipment for the condensation treatment, how to choose the efficient and...
Visualizza i dettagli -
Semiconductor Temperature Forcing System Thermal Flow Hood for DUT Testing
847The semiconductor temperature forced system (TFS), thermal flow meter and thermal flow hood are important equipment used to test the performance of semiconductor devices under different temperature conditions. These equipment are usually u...
Visualizza i dettagli