Istruzioni per il rilevamento dei guasti del compressore del termostato di riscaldamento e raffreddamento a semiconduttori
In the semiconductor heating and cooling thermostat, the compressor is one of its core components. Once it fails, it will affect the operation of the whole system. How to solve the fault is better?
The faults of semiconductor heating and cooling thermostat compressors can be divided into motor faults and mechanical faults (including crankshafts, connecting rods, pistons, valve plates, cylinder head gaskets, etc.). Mechanical failure often causes the motor to overload or even stall, which is one of the main causes of motor damage.
The compressor motor load includes the load required to compress the gas and the load required to overcome the mechanical friction. If the pressure ratio is too large, or the pressure difference is too large, the compression process will be more difficult; the frictional resistance caused by the lubrication failure will increase, and the motor stall in extreme cases will greatly increase the motor load. Lubrication failure and increased frictional resistance are the primary causes of load anomalies.
The short circuit caused by the metal shavings of the compressor, the metal chips trapped in the windings are the main culprit for the short circuit and the low grounding insulation value. The normal vibration of the compressor during operation and the twisting of the winding by the electromagnetic force at each start-up will promote the relative motion and friction between the metal chips interposed between the windings and the winding enameled wire. Sharp edges and swarf can scratch the enameled wire insulation and cause a short circuit.
Compressor contactor problems, contactors can meet demanding conditions such as fast cycling, continuous overload and low voltage. They have a large enough area to dissipate the heat generated by the load current, and the choice of contact material prevents soldering at high currents such as startup or stall. In order to be safe and reliable, the compressor contactor must simultaneously disconnect the three-phase circuit. The method of disconnecting the two-phase circuit is not recommended.
The rated current of the compressor contactor must not be lower than the rated current on the compressor nameplate. Contactors with small specifications or poor quality cannot withstand compressor start-up, large current surges during stalling and low voltage, and are prone to single-phase or multi-phase contact jitter, soldering or even falling off, causing motor damage.
Semiconductor heating and cooling thermostat compressors may have more faults. It is not recommended for users to solve them themselves. It is recommended to contact the manufacturer for after-sales service.
Raccomandazioni correlate
-
Applicazione delle apparecchiature di circolazione a controllo uniforme della temperatura nel processo di distillazione
1765Distillazione raffreddamento riscaldamento applicazione
Visualizza dettagli -
The significance of temperature in IC testing
2485Every integrated circuit (IC) goes through two type of tests before it can be sold and used to build a product: the first is called a wafer test; the second is called final test. With the improvement of integrated circuit electrical test technolog...
Visualizza dettagli -
Application of jacketed reactor cooling and heating circulator in chemical reactions
1677jacketed reactor cooling and heating system application
Visualizza dettagli -
Nota applicativa del frigorifero a bassa temperatura per l'assemblaggio a freddo di parti di motori di automobili
1879L'assemblaggio del motore avviene in un ambiente a bassa temperatura, al di sotto dei 30°C, in un frigorifero a bassa temperatura. I principali produttori di motori automobilistici dispongono di officine di assemblaggio a bassa temperatura. I motori assemblati a bassa temperatura...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore