Dettagli del dispositivo di protezione del dispositivo di controllo della temperatura del fluido circolante
The circulating pump overload protection function is to cut off the main power of the circulating pump when the circulating liquid temperature adjustment device is too large. Press the green button when resetting; the red button is the stop button, which is used during the test. When frequent protection, please check whether the voltage is under voltage (undervoltage is less than 15%, the power protector is not working), undervoltage is increased into current, forming protection. At this time, a Phillips screwdriver can be used to adjust according to the “△” direction. Current.
Different circulating fluid temperature adjustment devices are equipped with different high and low voltage protectors. The high and low pressure protectors will protect the compressor with reference to the suction and exhaust pressure of the compressor to ensure the normal operation and operating life of the compressor. The high and low voltage protectors are divided into mechanical and electronic high and low voltage protectors. When the high and low voltage protectors are protected, manual reset is required. Press the red highlight button to reset. When the high and low voltage protectors generate protection, manual reset is required. Push the red arrow to reset. The electronic high and low voltage protector is automatically reset.
The circulating fluid temperature adjustment system provides a lot of accessories for equipment protection to ensure the safety and stability of the equipment. The over temperature protection has an independent high temperature temperature limit switch, which can set a relatively large temperature value through this temperature switch (please note) Meet the relatively large operating temperature range of the equipment and the temperature range of the heat transfer oil).
Inspiratory temperature protection with independent compressor suction temperature protector to protect the compressor from excessive suction temperature, ensure that it is within 65 °C (non-recycling liquid temperature adjustment device manufacturer authorization, do not modify, will directly affect the compressor Cooling capacity).
Circulating fluid temperature adjustment device The oil pressure difference protector is generally applied in large equipment. Depending on the equipment, the oil pressure difference protector is different. Press the upper ink green button when resetting. Other types of oil pressure difference protectors are similar. The reset button can be reset by itself. Other protections of the circulating fluid temperature adjustment device include phase protection, phase loss protection, overvoltage and undervoltage protection, leakage protection, and water shutoff protection.
The protection devices of different circulating liquid temperature adjustment devices are different. No matter what brand, the safety devices are more important. We need to pay attention to them. We must carefully check before purchasing to ensure the operation of the equipment.
Raccomandazioni correlate
-
Come scegliere la tubazione per il recupero dell'adsorbimento per condensazione?
1459Dispositivo vocs di recupero dell'adsorbimento della condensa al momento della selezione, la sua configurazione di sistema deve essere chiara per poter acquistare con fiducia, quindi, i punti di attenzione della conduttura vocs di recupero dell'adsorbimento della condensa, come scegliere? Condensa...
Visualizza dettagli -
Motor test bench environmental cabin option for new energy vehicles
1451Passenger car motor and commercial vehicle motor test bench can complete the stall torque and locked rotor current test, temperature rise test, continuous electric working characteristic test, motor maximum speed test, motor over speed test and fe...
Visualizza dettagli -
L'importanza dei refrigeratori per il collaudo delle batterie dei veicoli elettrici
1525L'importanza dei refrigeratori per il collaudo delle batterie dei veicoli elettrici
Visualizza dettagli -
Trattamento dei guasti ad alta temperatura delle apparecchiature di prova per gli shock termici
1698L'intera funzione della camera di prova per shock termico Wuxi Guanya LNEYA è controllata dal computer. Si tratta di un software auto-sviluppato con una buona interfaccia operativa, che rende il funzionamento e il monitoraggio dell'utente più semplice e intuitivo. La manutenzione...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore