How to deal with the equipment failure alarm of the recirculating chiller
What to do if there is a failure and alarm during the use of the recirculating chiller equipment? In order to ensure production, such problems need to be resolved quickly.
We must first understand the causes of failures and alarms, and adopt different solutions for different causes. Common recirculation chiller equipment failures and alarms include reverse phase alarm, contactor jam alarm, over-temperature protection alarm, abnormal pressure alarm, overload alarm, etc. No matter what kind of fault alarm, it can be known according to the alarm light and alarm signal information.
1. Recirculation chiller equipment reverse phase alarm
When a reverse phase alarm occurs in the recirculation chiller equipment, the circulating pump cannot be started. There are two reasons for the reverse phase alarm of the high and low temperature cold water circulation device. One is that the phase sequence of the three-phase power line is connected incorrectly, and the other is that the reverse protector fails. If the phase sequence of the three-phase power cord is connected incorrectly, just adjust the phase sequence directly. If the reverse phase protector fails, it needs to be replaced.
2. Contactor stuck alarm
Recirculation chiller equipment contactor stuck alarm, the over-temperature indicator will also be on, generally there are three reasons: one is the heating AC contactor stuck, the other is the computer board heating has been outputting, there is a problem, and the third is the over-temperature The protection switch operates incorrectly. When the contactor is stuck and alarms, the continuous heating of the heat transfer oil will cause danger, so deal with it in time.
3. Alarm for lack of media
In order to protect the heating pipe and circulating pump of the recirculating chiller equipment, the system will stop heating when there is a shortage of media. When there is a lack of media, check whether there is a lack of media (water or oil). If the water temperature meter shows that there is a lack of media, you can adjust the pressure value of the pressure switch to a lower value.
4. Overload alarm
When the recirculation chiller equipment has an overload alarm, check whether the circulating pump is overloaded. If the pump is overloaded, you can increase the overload current ampere.
When the recirculation chiller equipment fails and alarms, as long as it is dealt with in time, there will be no safety issues. LNEYA is a manufacturer of recirculating chiller equipment, equipped with an after-sales service system. For minor problems such as fault alarms, you can consult us sales@lneya.com for a faster and safer solution.
Raccomandazioni correlate
-
Come risolvere il problema del guasto al circolatore della pompa di refrigerazione?
1683I dispositivi di riscaldamento a refrigerazione sono necessari in molte applicazioni chimico-farmaceutiche e di laboratorio. Allora come risolvere il guasto del dispositivo di riscaldamento a refrigerazione è anche preoccupato di come risolverlo? 1. Guasto della pompa di circolazione La pompa...
Visualizza dettagli -
Punti di attenzione per l'ispezione giornaliera delle apparecchiature di controllo a bassa temperatura a meno 30℃
1545The low temperature control equipment at minus 30 degrees Celsius is a refrigeration unit or also called a refrigeration unit. The difference from the chiller is the temperature range. It is a commonly used low-temperature equipment in the industr...
Visualizza dettagli -
What kind of refrigerant is selected by industrial chillers in different industries?
1388The refrigeration temperatures required by different industries for industrial chillers are different, so the choice of refrigerants is also different. Therefore, when choosing an industrial chiller, you need to have a clear understanding of the r...
Visualizza dettagli -
Come viene installato il refrigerante nell'unità di condensazione vocs?
1971L'apparecchiatura di condensazione vocs è l'apparecchiatura di LNEYA per l'adsorbimento di condensazione di vari gas vocs. Tra questi, anche il refrigerante delle apparecchiature di condensazione vocs è indispensabile. Come deve essere trattato il refrigerante? Per i vari refrigeranti...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore