Come viene installato il refrigerante nell'unità di condensazione vocs?
The vocs condensing equipment is LNEYA’s equipment for condensing adsorption of various vocs gases. Among them, the refrigerant of vocs condensing equipment is also indispensable. So, how should the refrigerant be treated?
For various refrigeration and heating equipment, generally there are many types of refrigerants, mainly freon, unsaturated hydrocarbon refrigerant, saturated hydrocarbon refrigerant, inorganic compound refrigerant, azeotropic mixture refrigeration. These kinds of agents, etc., generally use environmentally friendly R404 or R22 refrigerant, so you can rest assured when using, do not worry about refrigerant pollution.
In general, vocs condensing equipment generally has two methods when installing refrigerant. One is to use the compressor to remove the valve through hole and directly inject the refrigerant liquid into the system. This method is relatively fast and safe, and is more suitable for filling in the system when it is vacuumed and there is no refrigerant. This method uses the pressure difference and height difference between the refrigerant in the cylinder and the system to discharge into the refrigeration system. Once the filling is insufficient, it can be changed to the suction side. Once it is filled on the high pressure side, Be careful not to start the compressor to avoid accidents.
Another method is to fill the suction port of the compressor suction valve. When using this method, pay attention to the compressor of the vocs condensing device. When filling the liquid, remember to start the compressor and not inject the liquid refrigerant. In order to avoid liquid shock in the vocs condensing equipment. This method is suitable for situations where the system is insufficiently filled and needs to be added.
Need to know more to run vocs condensing equipment, LNEYA’s own vocs condensing equipment, welcome everyone to buy.
Raccomandazioni correlate
-
Heat transfer oil circulation system refrigeration deterioration problem
1284I believe that many users have encountered the heat transfer oil circulation system after a long time of use, will feel the deterioration of the scene, LNEYA as a professional manufacturer to remind everyone, if you encounter these phenomena, user...
Visualizza i dettagli -
Semiconductor refrigeration heating cycle air system test description
945There are many test items in the refrigeration and heating circulating air system for semiconductors. So, how much do users know about out-of-channel testing? The out-of-channel test of the cooling and heating circulating air system for semiconduc...
Visualizza i dettagli -
Analysis of Common Faults in New Energy Vehicle Power Battery Test System
941If the new energy vehicle power battery pack leaks, the general fault manifestation mode: the meter OK light does not light, the meter prompts to check the power system, the high voltage system leakage fault, disconnect the battery pack and the b...
Visualizza i dettagli -
Analytical description of accessories used in low temperature chiller
837The low temperature chiller still uses a larger amount of cooling water equipment in our usual refrigeration equipment. When using it, you must first understand the principle of the low-temperature chiller and various accessories to better operate...
Visualizza i dettagli