Come viene installato il refrigerante nell'unità di condensazione vocs?
The vocs condensing equipment is LNEYA’s equipment for condensing adsorption of various vocs gases. Among them, the refrigerant of vocs condensing equipment is also indispensable. So, how should the refrigerant be treated?
For various refrigeration and heating equipment, generally there are many types of refrigerants, mainly freon, unsaturated hydrocarbon refrigerant, saturated hydrocarbon refrigerant, inorganic compound refrigerant, azeotropic mixture refrigeration. These kinds of agents, etc., generally use environmentally friendly R404 or R22 refrigerant, so you can rest assured when using, do not worry about refrigerant pollution.
In general, vocs condensing equipment generally has two methods when installing refrigerant. One is to use the compressor to remove the valve through hole and directly inject the refrigerant liquid into the system. This method is relatively fast and safe, and is more suitable for filling in the system when it is vacuumed and there is no refrigerant. This method uses the pressure difference and height difference between the refrigerant in the cylinder and the system to discharge into the refrigeration system. Once the filling is insufficient, it can be changed to the suction side. Once it is filled on the high pressure side, Be careful not to start the compressor to avoid accidents.
Another method is to fill the suction port of the compressor suction valve. When using this method, pay attention to the compressor of the vocs condensing device. When filling the liquid, remember to start the compressor and not inject the liquid refrigerant. In order to avoid liquid shock in the vocs condensing equipment. This method is suitable for situations where the system is insufficiently filled and needs to be added.
Need to know more to run vocs condensing equipment, LNEYA’s own vocs condensing equipment, welcome everyone to buy.
Raccomandazioni correlate
-
Come scegliere un evaporatore di prova per batterie di potenza?
1933The corrosion of ferrous metals by salt water is very strong, and its corrosion is more severe when it comes into contact with air. Therefore, as far as the production process permits, closed loops should be used as much as possible. For volatile ...
Visualizza dettagli -
Advantages of bearing cryogenic treatment equipment
1803One of the names of the ultra-low temperature freezer is the bearing cryogenic treatment equipment. Wuxi Guanya LNEYA's ultra-low temperature freezer is designed for large volume ratio; large capacity bearing capacity design; can set the temperatu...
Visualizza dettagli -
Come risolvere il problema dell'insufficiente capacità di raffreddamento del sistema del ciclo di raffreddamento dei semiconduttori?
1934Il sistema del ciclo di raffreddamento dei semiconduttori è un dispositivo per il raffreddamento della parte di riscaldamento dei semiconduttori. LushiA ricorda che se la capacità di raffreddamento è insufficiente durante il funzionamento, è necessario controllare in tempo se qualcosa è andato storto. W...
Visualizza dettagli -
The role of recirculating heaters in chemical and biological reaction instruments
1279Temperature Control: The recirculating heater provides a precise and stable temperature control environment, which is a crucial factor in chemical and biological reactions. Different chemical reactions and biological processes have spec...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore