Come risolvere il problema del guasto al circolatore della pompa di refrigerazione?
Cooling heating devices are required in many chemical pharmaceutical and laboratory applications. Then how to solve the failure of the refrigeration heating device is also concerned about how to solve it?
1. Circulating pump failure
The circulating pump fault is generally the thermal overload of the circulating pump. There are four main reasons for this fault: The first is that the outer circulating pipeline of the heat conducting oil is too long. At this time, it is necessary to shorten the outer circulation pipeline, reduce the bending of the outer circulation pipeline, and then click Equipment electrical cabinet surface thermal relay Reset button; the second is the circulation pipeline blockage, cooling and heating device which is good to tell everyone, check the circulation pipeline cleaning, install the filter, and then click the equipment electrical cabinet surface thermal relay Reset button; The third is that the circulating pump voltage is too low. It is recommended to measure whether the circulating pump voltage meets the specified range, improve the voltage environment, click the Reset button of the equipment electrical cabinet surface thermal relay; the fourth is that the thermal relay regulates the current too small. At this time, it is recommended to measure the pump current. Compare the range of thermal relays, Phillips screwdriver to properly rotate the thermal relay current, click on the equipment electrical cabinet surface thermal relay Reset button.
2. Sensor failure
A great possibility of sensor failure is wiring error. Once the fault is encountered, check the wiring situation. At this time, you should pay attention to two situations, one is sensor short circuit or temperature <-160 °C, and the other is sensor open circuit or temperature > 349 ° C.
If the sensor is short-circuited or the temperature is <-160 °C, it may be the fault of the sensor itself. At this time, it is recommended to replace the sensor (there is a spare sensor in the equipment slot). If the sensor is wired incorrectly, It is recommended to check the wiring (corrected circuit diagram) correction.
If the sensor is open circuit or the temperature is >349°C, it should be the fault of the sensor itself. It is necessary to replace the sensor in time (there is a spare sensor in the equipment slot). At this time, it is necessary to pay attention to whether the temperature is too high and the temperature is too high. Check whether the temperature is exceeded. Range, if the equipment is not powered, pay attention to check the power supply of the equipment.
These two faults of the cooling heating device are still relatively simple. I believe that everyone who has seen the sharing can solve it very quickly.
Raccomandazioni correlate
-
Metodo di raffreddamento per strumenti evaporativi da laboratorio in funzione
1377La scelta del giusto metodo di raffreddamento per un esperimento di evaporazione può avere un impatto inimmaginabile sulle prestazioni complessive del sistema, sull'economia e sull'efficienza. È necessario acquistare una macchina per la circolazione dell'acqua di raffreddamento come attrezzatura di supporto. Quando si pu...
Visualizza dettagli -
Reactor Heating Circulator Related Instructions
1690Currently, reactor heating circulators are used more in the chemical industry. So, what do users need to pay attention to after purchasing? With the development of society, the process level of reactor heating circulators is becoming more and more...
Visualizza dettagli -
Uso e manutenzione del sistema di controllo della temperatura in laboratorio/bioingegneria
15381. Read the equipment manual carefully before use, get familiar with the operation process and key instructions, and operate in strict accordance with the conditions specified in the manual. 2. When moving the laboratory/bioengineering temperatur...
Visualizza dettagli -
Sistema di riscaldamento a refrigerazione LNEYA star SUNDI-320/420W/430W
1824Oggi vi presenterò il modello del sistema di riscaldamento a refrigerazione di LNEYA: SUNDI-320/420W/430W. Ha tre tipi di intervallo di temperatura media: -30°C~180°C; -40°C~180°C; -40°C~200°C. Il sistema di controllo è in grado di programmare fino a 10 programmi...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore