Maintenance principle of fluorinated liquid TCU temperature control system
The working environment of the fluorinated liquid TCU temperature control system

Fluorinated liquid TCU temperature control system should be placed in a ventilated, dry and clean place;
(2) The distance between the fluorinated liquid TCU temperature control system and the partition is greater than 1m;
(3) The louver holes on both sides of the fluorinated liquid TCU temperature control system must not be obstructed or blocked
- After each use of the fluorinated liquid TCU temperature control system, it is necessary to wipe all kinds of stains, oils and solvents on the surface of the machine with a soft cloth to keep it clean;
3. If the fluorinated liquid TCU temperature control system has been used for more than six months, or the high/low pressure switch often fails, or the cooling capacity is reduced, the condenser needs to be cleaned;
4. If it is not an emergency, it is not allowed to close the fluorinated liquid TCU temperature control system by cutting off the main power supply; if the fluorinated liquid TCU temperature control system is not used for a long time in winter, first close the fluorinated liquid TCU temperature control system, and then close the main power supply. And drain the water in the system;
5. Try not to tighten the interface of the fluorinated liquid TCU temperature control system too tightly, and keep regular activities to avoid being locked;
6. Pay attention to observe the condition of the heat transfer oil in the TCU temperature control system of the fluorinated liquid. If there is any color change, you need to contact the heat transfer oil manufacturer;
7. When maintaining the TCU temperature control system of fluorinated liquid, it is necessary to purchase qualified accessories, and do not replace them at will, so as not to cause a fatal blow to the machine.


E-mail: sales@cnzlj.com
WhatsApp: 086 13912479193
Raccomandazioni correlate
-
Ultra-high temperature material cold and hot impact box refrigeration oil
1166The ultra-high temperature material impact test chamber test device has too much frozen oil in the evaporator, which can also cause insufficient cooling and cause slow cooling. The oil stored in the evaporator of the ultra-high temperature materia...
Visualizza i dettagli -
How to use high and low temperature circulation equipment in extraction and separation?
862With the continuous development of science and technology, high and low temperature cycle industrial temperature control equipment plays an important role in many fields, especially in the field of extraction and separation. This article wil...
Visualizza i dettagli -
Precautions for customers installing Lneya’s cryogenic industrial chillers
1198One. When installing low-temperature industrial chillers, you need to pay attention to some installation requirements. 1. The cryogenic industrial chiller should be installed directly in a horizontal position, do not install it upside down or dia...
Visualizza i dettagli -
Practical application of different compressors in the industrial chiller industry
909In the current refrigeration industry, the efficiency of the equipment is closely related to temperature. LNEYA tells you that the efficiency of the refrigeration equipment required under control has been improved. Then, the selection of the compr...
Visualizza i dettagli