Usage Details of High and Low Temperature Environmental Chambers
The enterprise users must have a certain understanding of the functions of the high and low-temperature environmental chamber after using them for a long time, but something detail of the high and low-temperature environmental chamber may still not be paid attention to, so the technology department of Wuxi LNEYA has specially reorganized the related matters of attention for everyone.
Professional manufacturer of high and low-temperature environmental chambers for sale
When delivering, the tilted angle of the high and low-temperature environmental chamber should not exceed 30°. When carrying, keep the body of the high and low-temperature environmental chamber vertically, do not place it inversely or horizontally. Besides, dragging the door handle or the condenser are prohibited, otherwise, the equipment may be damaged.
The high and low-temperature environmental chamber should be electrified regularly every month during the lengthy shutdown period, and the power-on time should be more than 1h.
Professional manufacturers of high and low-temperature environmental chamber insist on taking out the test samples after each test and wipe the workroom wall of the environmental chamber to keep the inner box clean.
Cleaning and balance of the circulating blade and condenser fan: Similar to that of the cleaning evaporator, because the working environment of the environmental chamber is different, a lot of small particles like dust will condense on the circulating blade and condenser fan. Hence, they should be cleaned regularly.
The power supply voltage of the high and low-temperature environmental chamber fluctuations, such as repeated power failure. In this case, it is suggested to suspend the use of high and low-temperature environmental chamber and close the power supply to prevent the burning of the compressor. Do not start the compressor immediately after the shutdown of the high and low-temperature environmental chamber. It should be stopped for 2-5 minutes before restarting.
The condenser of the high and low-temperature environmental chamber should be cleaned every three months. The condensing fan should be regularly overhauled and the condenser should be cleaned and dedusted so as to ensure its good ventilation and heat transfer performance.
High and low-temperature environmental chamber should be placed in a well-ventilated position with low humidity and smooth ground, 60 ~ 70 cm of use and maintenance space should be left around.
During the operation of high and low-temperature environmental chamber, the frequency of door opening should be minimized and the spillage of cold air should be reduced.
The usage details of high and low-temperature environmental chamber should be used by enterprise users in daily use.
Raccomandazioni correlate
-
Il punto di ingresso per la selezione dei refrigeratori industriali
1074Industrial chillers are refrigeration devices that assemble refrigerators, condensers, evaporators, expansion valves, control systems, and switch boxes on a common base or frame. According to the heat rejection method of the unit, it can be divide...
Visualizza i dettagli -
Introduzione all'uso del refrigeratore di precisione a prova di esplosione
1113Wuxi Lneya solves the problem of how to charge refrigerants in the absence of refrigeration. 1. Connect all kinds of equipment well, close the three valve when the vacuum pressure is down to 133.3Pa, remove the hose from the suction port of the va...
Visualizza i dettagli -
How to Carry On Industrial Low Temperature Chillerstest Of Choosing The Better Company?
1043No matter what chillers are used, we need to constantly learn about the relevant knowledge of the industrial-low temperature chillers. Which company's low - temperature chiller is better? Let me tell you, in order to help you to use the industrial...
Visualizza i dettagli -
Introduction of distillation principle and temperature cycle control device
944Distillation is a common method for purifying liquid substances and separating mixtures. The boiling point of the compound can also be measured by distillation, so it also has a certain significance for the identification of pure liquid organic co...
Visualizza i dettagli