The difference between air-cooled and water-cooled 15P refrigeration units
Because the demand conditions are different, when the selected 15P refrigeration unit is air-cooled and water-cooled, what is the difference?
The air-cooled 15P refrigeration unit contains a heat-insulating water tank and water pump in its body, which is very convenient for installation and movement. However, it requires a higher working environment because it is cooled by hot air circulation. Therefore, if the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect of 15 refrigeration units. In addition, if you want to put the refrigeration unit in a dust-free workshop with humidity requirements, then I advise you to modify the water-cooled. Because of the air-cooled refrigeration unit, water vapor is sprayed on the top of the machine to dissipate heat.
The water-cooled 15P refrigeration unit can be divided into open type, sealed type (some called box type) and screw type. It is necessary to declare that the water-cooled refrigeration unit must be additionally equipped with a cooling tower and a water pump for extracting hot water to dissipate heat. In order to achieve a better cooling effect.
Air-cooled 15P refrigeration units can be used on small systems, most of which are water-cooled. When the water is cold, the main engine is less than the air-cooled. In other words, the cooling efficiency of the water-cooled unit will decrease relative to the long-term operation, and the air cooling will not.
The air-cooled 15P refrigeration unit has a slightly higher investment than the water-cooled 15P refrigeration unit, but the annual operating cost is lower than that of the water-cooled refrigeration unit. The construction cost of the equipment room is relatively small in various refrigeration unit cold and heat source systems. The cost is about half the cost of water-cooled or boilers. The noise and volume of air-cooled chillers are larger than those of water-cooled units. This requires attention.
There is a certain difference between the air-cooled and water-cooled units of the refrigeration unit. I hope that you can understand the proper 15P refrigeration unit model.

Raccomandazioni correlate
-
Come risolvere il problema dell'insufficiente capacità di raffreddamento del sistema del ciclo di raffreddamento dei semiconduttori?
1271Il sistema del ciclo di raffreddamento dei semiconduttori è un dispositivo per il raffreddamento della parte di riscaldamento dei semiconduttori. LushiA ricorda che se la capacità di raffreddamento è insufficiente durante il funzionamento, è necessario controllare in tempo se qualcosa è andato storto. W...
Visualizza i dettagli -
The importance of chiller compressors
1087In the operation of the precision chiller, the compressor is a more important part. If we want to understand the chiller, we have to understand the compressor. Most precision chiller compressors have a thermal switch inside. The function of this s...
Visualizza i dettagli -
Uso e manutenzione del sistema di controllo della temperatura in laboratorio/bioingegneria
9291. Read the equipment manual carefully before use, get familiar with the operation process and key instructions, and operate in strict accordance with the conditions specified in the manual. 2. When moving the laboratory/bioengineering temperatur...
Visualizza i dettagli -
Semiconductor refrigeration heating cycle air system test description
951There are many test items in the refrigeration and heating circulating air system for semiconductors. So, how much do users know about out-of-channel testing? The out-of-channel test of the cooling and heating circulating air system for semiconduc...
Visualizza i dettagli