What is a laboratory glycol chiller What should I pay attention to
The laboratory glycol chiller is a common
cooling equipment in the laboratory. It is generally used to achieve the
temperature requirement of the cold source. What are the benefits?
1. Why choose a laboratory glycol chiller:
The single-machine self-cascade
refrigeration technology adopted has fast refrigeration speed, low noise and
simple installation. There are many sizes and models of laboratory
low-temperature refrigeration cycle devices. Users can choose models according
to their own needs, and can also choose isolation and explosion-proof options.
2. Commonly used refrigerants in laboratory
glycol chillers:
Commonly used water, brine, chlorinated
solution, and ethylene glycol in laboratory cryogenic refrigeration cycle
devices, the performance, price, and heat capacity of each refrigerant are
different, so the choice can be selected according to the needs.
The freezing point of ethylene glycol is
relatively low, the use temperature is -50 degrees, the performance is
relatively temperature, the price is cheaper, but it is corrosive. The
chlorine-containing solution has a low freezing point, high volatility, and
corrosiveness. The applicable temperature range is -50 to -100°C. Water has
a large specific heat, low density, low price and easy availability. It is
suitable for occasions where the refrigeration temperature is above 0°C. The salt
water can lower the freezing point temperature and expand the cooling range. It
is suitable for medium and low temperature refrigeration systems.
3. Points for attention when using the
laboratory glycol chiller:
A. Before use, you need to check to see if
the location of the device is correct to avoid problems during use.
B. When using the laboratory glycol
chiller, follow the operating instructions for operation, including turning on
and off the machine.
C. Pay attention to good maintenance work,
and perform regular maintenance regularly.
D. When the laboratory glycol chiller fails
during use, it should be solved in time. Some common failures have information
in the instruction manual, which can’t be solved. Contact the manufacturer to
solve it.
Riassumere
Laboratory glycol chillers are used in many
industries such as chemicals, new energy, components, industries, etc., and you
need to pay attention to the quality of choice when choosing. Global consulting
sales@lneya.com.
Raccomandazioni correlate
-
How do semiconductor CVD and PVD chillers work?
1018The working principle of the chillers used in semiconductor chemical vapor deposition (CVD) and physical vapor deposition (PVD) processes is mainly to remove the heat generated during the process by circulating cooling water or special coola...
Visualizza i dettagli -
LNEYA combatte contro "NCP" e riprende la produzione in sicurezza
1298The NCP casts a haze over the new year of 2020, but the moment when everything recovers will never be absent. At present, for many enterprises across the country, their operating pressure and shoulder responsibility are very heavy. However, LNEYA ...
Visualizza i dettagli -
Metodo efficiente per l'estrazione di cannabinoidi totali utilizzando un sistema di raffreddamento criogenico di processo
1165Sebbene le piante di cannabis siano state utilizzate per scopi terapeutici per migliaia di anni, la scienza moderna ha identificato steroidi, flavonoidi e più di 100 composti terapeuticamente attivi noti come cannabinoidi. Grazie alla significativa sinergia tra...
Visualizza i dettagli -
Main points of maintenance of flash high and low temperature test chiller
949Buyers of flash high and low temperature test chiller are increasing day by day. Many people find that the service life is greatly reduced after purchasing. Therefore, operation management and maintenance personnel must have certain professional k...
Visualizza i dettagli