How to protect the zero-86 degree low temperature refrigerator?
The structure of the scroll compressor and the piston compressor in the low-to-86 degree low-temperature refrigerator is different, and it cannot be reversed. The reverse phase of the three-phase power supply of the low-zero-86 degree low-temperature refrigerator will cause the compressor to reverse, so it is necessary to install reverse phase protection. To prevent the refrigeration press from reversing. After the reverse phase protector is installed, the compressor can be operated in the normal phase and does not operate in the reverse phase. When the sub-zero-86 degree low temperature refrigerator is reversed, just reverse the two lines of the power supply and change to the normal phase.
In order to protect the compressor under high load operation or insufficient refrigerant, an exhaust temperature protector needs to be installed in the subzero-86 degree low temperature refrigerator system, and the exhaust gas temperature is set within the range of 130±5°C. The compressor is stopped. This temperature value refers to the position detection temperature of the compressor exhaust pipe within 10 cm from the outlet.
In order to protect the operation of the subzero-86 degree low temperature refrigerator compressor when the refrigerant is insufficient, a low pressure switch is required. When the temperature is set to 0.03 mpa or more, the compressor stops running. Zero-to-86 degree low-temperature refrigerator compressors operate in the state of insufficient refrigerant, then the temperature of the compressor part and the motor part of the sub–86 degree low-temperature refrigerator will rise instantaneously. At this time, the low-voltage switch of the lower-86 degree low-temperature refrigerator can be Protection against damage to the compressor and motor burnout that cannot be protected by the internal temperature and exhaust temperature protectors.
In order to prevent the zero-to-86 degree low-temperature refrigerator from running 24 hours, the high-load operation of the lower-86 degree low temperature refrigerator compressor, the electromagnetic switch is poor, the overcurrent caused by the holding shaft, or the motor is burnt due to the motor temperature. The internal thermostat is installed inside the compressor. It is installed on the neutral contact of the three-phase motor. When the subzero-86 degree low temperature refrigerator is abnormal, the motor is protected by cutting off the three phases at the same time.

The zero-to-86 degree low-temperature refrigerator electromagnetic switch is used to control the compressor operation of the zero-86 degree low-temperature refrigerator. The shutter is closed for the purpose of installation. When installing, it should be kept vertical. If the installation is wrong, the joint spring pressure will change and noise will be generated. It causes phase loss operation. For models with a compressor with a direct power failure protector, there is no need to load the protector.
The protection device of the minus-86 degree low temperature refrigerator is very necessary. All the users are advised to choose the time, if it is capable, Wuxi Guanya LNEYA recommends the explosion-proof zero-86 degree low temperature refrigerator.
Raccomandazioni correlate
-
Trouble shooting method for water cut off of cooling system driven by wheel motor
988Long-term use of the wheel motor to drive the cooling system can encounter any kind of failure. For the wheel-side motor drive cooling system, if there is a water cut problem, it is very dangerous and must be dealt with in a timely and effective m...
Visualizza i dettagli -
LNEYA trattamento del pianto super profondo con il buon senso
959For ultra-deep cold processing equipment, failure to pay attention to the use of the equipment may cause equipment failure. Before using the water-cooled ultra-cry cryogenic treatment, it should be checked whether all the valves between the equipm...
Visualizza i dettagli -
What is the refrigerant of circulating water cooling equipment?
967Different industries require different refrigeration temperatures for circulating water cooling equipment, so the selected refrigerants are also different. When choosing circulating water cooling equipment, you also need a clear understanding of t...
Visualizza i dettagli -
Applicazione industriale dei refrigeratori raffreddati ad acqua
974I refrigeratori, comunemente noti come congelatori, refrigeratori, refrigeratori, refrigeratori, refrigeratori, ecc. sono ampiamente utilizzati in vari settori industriali, per cui i nomi sono numerosi. Il principio della sua natura è quello di un dispositivo di raffreddamento versatile che rimuove il vapore liquido attraverso un...
Visualizza i dettagli