How to maintain the lubrication system of water-cooled chillers
Medium-sized water cooled chiller,
refrigeration temperature range from -80 ℃~ -30℃, safe,
reliable, rapid cooling for the liquid, widely used in petrochemical, medical,
pharmaceutical, biochemical and freeze-dried, military and other high-tech industries.
When the water cooled chiller is below 80℃ ~ 30℃ below zero
in the running system, people pay more attention to refrigerator, frozen water
cycle system and electric control system, so the lubrication system is often
overlooked. However, this system is also very important to the water cooled
chiller. The maintenance of the water cooled chiller is indispensable, now we
are going to tell you something about it.
1. Observe the normal oil surface, oil
temperature and oil pressure in the daily inspection.
2. Regularly check the oil quality
according to the oil change index stipulated in the frozen lubricating oil, and
replace or supplement the filtered new oil.
3. Pay attention to check and adjust the
end face clearance of the oil pump in the middle and overhaul, and replace the
pump when necessary. The end face clearance of the pump varies from 0.03 to
0.08mm. Please refer to the assembly technical requirements and factory
regulations of the pump for concrete value.
4. Regularly replace or clean the filter
core, pipeline, and crankcase.
The maintenance of the lubrication system
of the water cooled chiller requires techniques, which mainly involves the
performance of the compressor’s main engine. It is recommended to be operated
by professionals to avoid unnecessary losses.
If you are purchasing our LNEYA
water-cooled chiller, you can contact our after-sales team. If you have
purchase needs or questions in this regard, you can also contact our team
sales@lneya.com, we will reply to you as soon as possible.
Raccomandazioni correlate
-
Risoluzione dei problemi di guasto del sistema di refrigerazione delle apparecchiature di prova per l'invecchiamento dei materiali a bassa temperatura
1734È molto importante anche la manutenzione regolare del sistema di prova dell'invecchiamento a bassa e ad alta temperatura dei materiali e la risoluzione dei problemi del sistema di refrigerazione. Ecco alcuni suggerimenti. 1. Scarico a doppia pressione, dissipazione del calore...
Visualizza dettagli -
Trouble shooting method for water cut off of cooling system driven by wheel motor
1602Long-term use of the wheel motor to drive the cooling system can encounter any kind of failure. For the wheel-side motor drive cooling system, if there is a water cut problem, it is very dangerous and must be dealt with in a timely and effective m...
Visualizza dettagli -
-
Il motivo dell'esistenza del frigorifero criogenico nell'industria della produzione di parti di utensili
1366Il trattamento criogenico viene applicato agli utensili usurati, ai materiali delle fustelle e successivamente esteso agli acciai legati, al carburo cementato, ecc. Questo metodo è in grado di modificare la struttura interna dei materiali metallici, migliorando così la meccanica e la lavorazione...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore