The Reasons of Frosting on Ultra low Temperature Recirculating Chillers
Frosting will appear when many users take advantage of refrigeratori a ricircolo a bassissima temperatura, while some are not. It is confusing and whether it is relevant to refrigeration.
First of all, why does ultra low temperature recirculating chillers frost? To sort it out, we can turn our eyes on the reasons of direct-cooling ultra low temperature recirculating chillers. The frost is a white crystal of vapour which will congeal on the surface of ultra low temperature objects.
The air will frost on the surface of the inner wall inside ultra low temperature recirculating chillers, which is the root cause. It will affect the heat transfer efficiency, resulting in the decline of refrigerating capacity, so the users should remove it manually.
We understand why the ultra low temperature recirculating chillers will frost on one hand, and for the other hand the air-cooled one is frostless. Are their reasons against each other? The principle of that is the air-cooled ultra low temperature recirculating chillers applies air to refrigerate. When high temperature air flows through the inner evaporator, both of them will change the heat directly because they are in opposite conditions so that the temperature of air will lower.
Meanwhile, cool air is blown in the ultra low temperature recirculating chillers, which is exactly what air-cooled one uses for cycling constantly to reduce its own temperature. However, vapor always exists in the air, so it becomes solid when it freezes, which shows that whenever heat transfer happens, frosting will be in the ultra low temperature recirculating chillers.
In fact, air-cooled ultra low temperature recirculating chillers is carried with frost, but only on the surface of the evaporator. When opening the door, we can not see it because the frost is inside. Thus, we call it as frostless on the whole.
Therefore, we make it clear why ultra low temperature recirculating chillers is out of frosting.
Raccomandazioni correlate
-
Ultra Low Temp Chiller Compressor Common Protection Instructions
846The ultra low temp chiller compressor is a relatively important part of all its components. In the course of operation, certain protective devices are needed to help the compressor operate safely. What specific protection? Let's take a look! The m...
Visualizza i dettagli -
Metodo di ispezione del dispositivo di prova ambientale delle celle a combustibile comuni
1159During the cooling process of the fuel cell environmental test device, there is a chance of dripping inside. This is not a normal phenomenon used by the fuel cell environmental test device, but is caused by improper installation. After the fuel ce...
Visualizza i dettagli -
CIPM China [C-48-2] welcomes new and old customers!
1272The 58th (Fall 2019) National Pharmaceutical Machinery & ChinaInternational Pharmaceutical Machinery Expo will be held at the Chongqing International Expo Center from November 5th to November 7th, 2019. It is recognized by the industry as prof...
Visualizza i dettagli -
How to maintain and extend the service life of the dynamic temperature control system?
950Dynamic temperature control system is a fully enclosed refrigeration and heating temperature control device that provides cold and heat sources. The service life is related to the usual maintenance and cleaning. Dynamic temperature control system...
Visualizza i dettagli