LNEYA data center liquid cooling solutionLiquid Cooled CDU Distribution Unit
Cold plate liquid cooling CDU-15kW
LNEYA relies on its strong R&D, construction, and operation and maintenance capabilities in the field of data centers to launch a cold-plate liquid-cooled CDU with a new air-liquid architecture. Building construction and renovation of old machine rooms, with excellent PUE indicators throughout the year, green, energy-saving, safe and reliable operation.

Applications: Renovation of small and medium-sized old data center
Energy saving, high efficiency and superior performance
Air-liquid structure, heat dissipation up to 12KW, green and energy-saving, system PUE≤1.2
Standard plug-in design, flexible layout, height is only 5U. Improve the rate of cabinets in the computer room
Front, side inlet, rear outlet air duct design, optimized airflow organization, cold and hot aisle isolation
Easy to install and easy to maintain
Does not involve the primary side pipeline layout, reducing the risk of pipeline laying, engineering quantity and water entering the machine room
Modular design, highly integrated products, easy installation, easy maintenance interface, standard quick connection, two-way cut-off of the flow channel, direct plug-in and maintenance of the pipeline on site
Renovation is simple. The old computer room can rely on the existing refrigeration system, only
Intelligent optimization of remote operation
System status analysis, real-time regulation of refrigerant flow, flow velocity and air volume, load balancing
Liquid product touch screen on-site and host computer remote centralized monitoring, human-computer interaction
Friendly interface
Anti-condensation control, liquid leakage detection, enhanced anti-interference design, high stability Support Modbus-RTUTCPMP communication
Safe and reliable system stability
Double-pump 2N redundant frequency conversion design, automatic switching in case of failure; when the two pumps are running at the same time, overclocking can increase the heat transfer by about 10%
Low-noise dual-fan design, when a single fan fails, the entire liquid cooling system will not stop
Expansion tank for pressure stabilization, full-scale group system design, leakage concealment reduction
High-efficiency pure copper micro-channel heat exchanger, highly compatible with pure steel liquid cold plate, improving system reliability
Introduction to cold plate liquid cooling system products and equipment
Introduction to cold plate liquid cooling chiller
caricamento...
已经是到最后一篇内容了!
Forniamo consulenze gratuite e soluzioni complete 7*24


E-mail: sales@cnzlj.com
WhatsApp: 086 13912479193
Raccomandazioni correlate
-
Introduction to cold plate liquid cooling system products and equipment
1080Introduction to cold plate liquid cooling chiller
Visualizza i dettagli -
Immersion phase change liquid cooling system
1108What is immersion phase change liquid cooling system?
Visualizza i dettagli -
Descrizione dettagliata delle tubazioni delle apparecchiature del ciclo di refrigerazione e riscaldamento
1079When the refrigeration and heating cycle equipment is in operation, the user will find that whether or not the fully enclosed pipeline affects the overall performance. The LNEYA refrigeration and heating cycle equipment adopts a fully enclosed cyc...
Visualizza i dettagli -
Analisi delle cause del rumore generato dal funzionamento dei refrigeratori a bassa temperatura
993Noise is common in the operation of industrial equipment. There are many reasons for noise, which may be caused by some environmental problems in the installation. When noise is generated, we must first confirm the cause and whether it is an inter...
Visualizza i dettagli -
Congelatore per assemblaggio a freddo di pezzi per l'industria pesante
766Nell'industria pesante, i congelatori di assemblaggio a freddo (chiamati anche congelatori industriali o congelatori criogenici) sono utilizzati per raffreddare e conservare pezzi o materiali di grandi dimensioni per soddisfare requisiti di processo specifici. Queste apparecchiature sono spesso utilizzate...
Visualizza i dettagli -
Dove servono i refrigeratori d'acqua antideflagranti?
834Explosion-proof refrigeration unit water chillers (explosion-proof chillers) are mainly used in environments with explosion risks to ensure the safety and reliability of the cooling process. This type of equipment is specially designed to ...
Visualizza i dettagli
Invia per la consultazione
Vi risponderemo entro 24 ore