Come risolvere il problema delle scarse prestazioni di raffreddamento del sistema di circolazione dell'olio di trasferimento del calore?
Some heat-conducting oil circulation systems will not be as good as before after 3 months of use. At this time, it is recommended to contact the professional after-sales department to check the user’s power supply and whether the equipment is normal. The test heat conduction oil circulation system is set to cool operation, and the working pressure is 4.5kg/cm2. Considering that the variable frequency heat transfer oil circulation system uses the electronic expansion valve to throttle, it is not accurate to judge the fault only by the working pressure. Therefore, the outdoor working current is measured again. The measurement finds that the working current is only 10.5A, which is much smaller than the rated value, and the fault is determined as “ Lack of refrigerant.”
Then, first find out the refrigerant leakage part of the heat transfer oil circulation system. Try to open the mechanism heat, use the washing spirit liquid to coat the joints for leak detection, and find that the joint is not tightened, which is the cause of refrigerant leakage. After tightening, check the leak again to make sure the pipeline is intact and then charge the system with refrigerant.
The heat transfer oil circulation system uses the “constant flow charging method”. In order to ensure the accuracy of the refrigerant charge, the exhaust pipe temperature sensor is first suspended. After starting up, use the ammeter to measure the current on the outdoor power line of the heat transfer oil circulation system. As the refrigerant replenishment increases, the current will gradually increase. When the rated current value reaches 12A (the 70-type inverter cabinet is 16A), the refrigeration The dosage of the agent is appropriate. This method is often used during home repairs.
If the heat transfer oil circulation system is overhauled or the leak is too large, and the refrigerant has leaked out in the system for a long time, the refrigerant can be charged by the quantitative method. First, the system is evacuated, and vacuuming or external air evacuation can be used. Then, the system is filled with refrigerant according to the standard. If the external air is emptied, it should be slightly less than the standard amount and in the cold state. These are the reasons why after a few months of use, suddenly become uncooled or poorly cooled.
LNEYA provides professional heat transfer oil circulation system, which is mainly engaged in professional brand equipment, with safe and reliable quality. If you need it, please come and purchase it.
Raccomandazioni correlate
-
Prestazioni della camera di prova dell'umidità ad alta e bassa temperatura
18311. Ha un'ampia gamma di controllo della temperatura, che può soddisfare le esigenze degli utenti.2. Con un metodo unico di controllo della temperatura bilanciato, con una capacità di riscaldamento stabile e bilanciata, è possibile effettuare un controllo della ...
Visualizza dettagli -
Necessity of temperature control in fractional distillation of distillation
1465The pharmaceutical and chemical industry involves many chemical reactions, and with the continuous development of the pharmaceutical and chemical industry, there is a great demand for such instruments. The traditional open cooling and heating con...
Visualizza dettagli -
What is the temperature of the cryogenic cooling circulator?
1630The LNEYA cryogenic cooling circulator has a cooling temperature range from -125 degrees to -20 degrees. It adopts a computer cascade temperature controller and a PT100 temperature sensor, and the temperature control accuracy can reach ±0.1 degree...
Visualizza dettagli -
Closed hot and cold cycle machine compressor fault repair process
1449LNEYA's closed-type hot and cold cycle machine adopts single-machine self-cascading refrigeration technology, and its compressor also uses the brand compressor, which is more stable in performance. Therefore, it is easy to choose a series of compr...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore