Manutenzione del sistema di controllo del riscaldamento con raffreddamento a glicole
Apart from the attention needed during the daily use, the regular check and maintenance of Glycol Cooling Heating Control System are also very important. In order to help all of you learn to use Glycol cooling heating more efficiently, Guanya Refrigeration sort out related maintenance, so that you can use it in time.
Screw Compressor
Screw compressor is a very important part of ethylene glycol refrigerator, and the compressor is directly related to the stability of the unit. If the compressor has something wrong, In view of the high precision of the assembly precision of the screw compressor, the factory is usually required to carry out the maintenance, so it needs to be paid more attention in the ordinary use process in using.
Condensers and Evaporators
Is there is something wrong with the Glycol cooling heating control system, in view of the high precision of the assembly precision of the screw compressor, the factory is usually required to carry out the maintenance, so the compressor needs to be paid more attention in the ordinary use process.
Washing of condensers and evaporators
The cooling water of the water-cooled condenser of glycol refrigeration unit is open loop circuit. The circulating water is usually used by the cooling tower. When calcium the content of salt and magnesium salt in water is large, it is easy to decompose the fouling between the pipe and rock, and the heat transfers. Once the scale of the condenser of glycol cooling system is too thick, the cross section of the cooling water will decrease, the water volume will decrease and the condensing pressure will increase. Therefore, when the water quality of the cooling water is poor, the cooling water pipe should be washed at least once a year to remove scale and other contaminants. Of course, not only glycol cooling system but other other related cooling equipment used for a period of time, their maintenance knowledge is needed to learn in everyday use.

Raccomandazioni correlate
-
Failures of Heating Cooling Circulators
950The heating cooling circulator can be used in many chemical pharmaceuticals and laboratories. Then, how to solve the failures of the heating cooling circulator?Failure of circulating pumpThe failure of the circulating pump is generally the heat ov...
Visualizza i dettagli -
How to remove ultra-low temperature refrigerator shell and tube condenser scale?
1104Low-temperature refrigerator ultra-low temperature condenser scale removal In general, we have three methods, namely mechanical descaling, chemical pickling and descaling, and electronic magnetic water separator descaling. Low-temperature refriger...
Visualizza i dettagli -
Risoluzione dei guasti alle ventole del sistema di raffreddamento del gruppo motore
958La ventola è generalmente installata all'estremità superiore del sistema di raffreddamento del gruppo motore, mentre alcuni clienti scelgono di installarla lateralmente in base alle normative. I refrigeratori a vite che utilizzano ventole per dissipare il calore sono chiamati...
Visualizza i dettagli -
Come scegliere il refrigeratore a vite raffreddato ad acqua
1235Compared with the similar chillers, the screw type water-cooled chiller has many advantages. We as one of the top chiller manufacturers share you more. 1. The temperature of the heat conducting liquid can be adjusted to any temperature you want, a...
Visualizza i dettagli