Precautions for the use of molecular distillation cooling and heating temperature control
The SUNDI series of LNEYA refrigeration and heating temperature control system are used together to control the temperature in the process of molecular distillation. What should be paid attention to in use?
If the molecular distillation method cannot pump up the vacuum, it is necessary to check whether the joints, the interface are sealed, the sealing ring and the sealing surface are effective; Cracks, chipping, damage phenomena. Each grinding port of the molecular distillation method, the sealing surface sealing ring and the joint need to be coated with a layer of vacuum grease before installation. Before the heating tank is powered on, water must be added. Dry heating without water is not allowed. Screw it into the safety hole to avoid damage to the flask. Glass parts should be handled with care, washed, dried or dried before installation.
The heater of the molecular distillation method must be equipped with a safety valve. The steam pressure in the heater should not exceed 0.01Mpa. The safety valve should be checked frequently for faults, and the steam valve should be closed under any circumstances. When the molecular distillation method circulation pump fails and stops running, the steam should be turned off immediately, and the operation of the molecular distillation method pump should be checked frequently, whether the oil level is normal, and the amount of cooling water. Always observe the motor current and motor temperature of each equipment of the molecular distillation method. It is strictly forbidden to cut off any part of the material in the molecular distillation method under any circumstances. When the ambient temperature of the equipment is below 0 °C, the accumulated water in the equipment and its pipelines should be drained to avoid freezing or blocking the pipelines.
If the molecular distillation method is used improperly, it may lead to certain failures of the temperature control equipment, so it is necessary to pay attention to the above operations.
Raccomandazioni correlate
-
Qual è la differenza tra i refrigeratori a glicole e i refrigeratori ad acqua?
1591Sia i refrigeratori di glicole che i refrigeratori possono essere utilizzati per dissipare in modo soddisfacente il calore generato durante la produzione. La differenza fondamentale tra i due tipi di refrigeratori è la variazione del loro punto di congelamento e delle loro capacità di trasferimento del calore. ...
Visualizza dettagli -
What are the applications of steam circulators in chemical industry?
1528The steam circulator in the chemical industry is a temperature control equipment in the pharmaceutical and chemical industry. When users operate, they need to understand the performance and maintenance knowledge in order to operate the equipment e...
Visualizza dettagli -
Condizioni ambientali per l'installazione di refrigeratori raffreddati ad aria
1642Come tutti sappiamo, l'installazione della maggior parte delle macchine deve essere adeguata all'ambiente e alle condizioni. Naturalmente, i nostri refrigeratori industriali raffreddati ad aria non fanno eccezione. Se il refrigeratore raffreddato ad aria non viene installato per la prima volta, porterà un sacco di ...
Visualizza dettagli -
Multi-stage refrigeration system centrifugal compressor repair instructions
2081After the centrifugal compressor of the cascade refrigeration system is disassembled, the dimensions of each journal (cooperating with the impeller, bearing, coupling, etc.) are measured with an outer diameter micrometer to calculate the roundness...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore