Disadvantages and advantages of general heat transfer oil heating circulation system
The heat conduction oil heating circulation system adopts a fully closed loop structure to directly act on the heat energy to the heated medium. Its advantages are:
(1) Due to the continuous renewal of the heat transfer surface, the heat loss is small;
(2) The temperature field distribution state of the medium can be changed during operation;
(3) Multiple units can be used in parallel. The closed circulation system has a wide range of applications, such as various boilers, industrial furnaces, air preheaters, dryers, ovens and other places that require heat transfer.
But it also has many shortcomings, mainly as follows:
(1) Air resistance is easy to occur when there is gas or liquid in the system;
(2) It is not easy to realize automatic control and remote control;
(3) It is difficult to adapt to high temperature and high pressure occasions.
LNEYA’s heat conduction oil heating circulation system adopts the complete cooling process to achieve 300°C to 50°C cooling, which can continuously increase and decrease the temperature. There is no oil mist volatilization at high temperature, and the heat transfer oil will not be oxidized and browned. It has the function of correcting the internal circulation temperature probe PT100. With safety protection functions, such as self-diagnosis, high-voltage pressure switch, overload relay, thermal protection device, etc. When the system is running, the pressure will not increase due to high temperature, and the heat transfer medium will be automatically replenished at low temperature.
Raccomandazioni correlate
-
Lneya’s high and low temperature cooling circulator instructions
1664The high and low temperature cooling circulator is developed and produced by LNEYA using its refrigeration and heating temperature control technology. When using high and low temperature cooling circulators, users are advised to use them according...
Visualizza dettagli -
Applicazione e principio di funzionamento del refrigeratore ad acqua
1452Applicazione e principio di funzionamento del refrigeratore raffreddato ad acquaIl refrigeratore raffreddato ad acqua è un tipo di frigorifero industriale a bassa temperatura LNEYA di Wuxi Guanya. Un singolo compressore può raggiungere i -152 gradi Celsius di raffreddamento e refrigerazione. Potenza dell'apparecchiatura,...
Visualizza dettagli -
Come scegliere un refrigeratore di idrogeno?
1355Il refrigeratore (chiamato anche sistema di raffreddamento o chiller) nel processo di produzione dell'idrogeno è uno dei componenti chiave per garantire il funzionamento stabile delle apparecchiature di produzione dell'idrogeno. Il refrigeratore aiuta a mantenere l'elettrolizzatore, il reattore e...
Visualizza dettagli -
Come risolvere il problema del rumore del compressore nei refrigeratori industriali a bassa temperatura?
1847Nei refrigeratori industriali a bassa temperatura, il funzionamento del compressore produce rumore, ma solo per la differenza di dimensioni del suono. In generale, se il rumore è eccessivo, si verificano alcuni problemi. Quindi, come risolvere il problema del rumore del compressore?
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore