Lneya’s high and low temperature cooling circulator instructions
The high and low temperature cooling circulator is developed and produced by LNEYA using its refrigeration and heating temperature control technology. When using high and low temperature cooling circulators, users are advised to use them according to their instructions.
The high and low temperature cooling circulator is a device that uses mechanical refrigeration to obtain low temperature heating tube heating to obtain high temperature, a leak-free shielding pump as a circulation pump, a double-layer glass reaction bath, a stainless steel sandwich reaction kettle and the like. Before using the high and low temperature cooling circulator, open the wooden box and first install the inlet and outlet valves on the liquid inlet. (Note: The upper and lower sides of the machine are marked with inlet and outlet ports, the valve is a shut-off valve, the valve medium flows in a direction, and the valve is marked with a flow direction. The valve and the reaction kettle are docked with a hose, and the inlet and outlet of the reaction kettle should be driven in, out, and react. Keep the liquid in the kettle. Open the high and low temperature tank and add the liquid to the machine to open the machine’s circulation switch, let the liquid circulate throughout the system. (Note: To evacuate the air in the system) The cooling medium should meet the conditions of use. That is, it does not freeze under low temperature conditions, and does not boil under high temperature conditions)
If the high and low temperature cooling circulator requires a temperature of 150 ° C, set the temperature control table to 150 ° C to turn on the heating switch and the cycle switch, and the machine will start working. When the material needs to be cooled to room temperature at high temperature, it is necessary to turn off the heating and turn on the pre-cooling. At this time, the material can be cooled to room temperature by cooling. When the material needs to be lower than room temperature, first reduce the material to room temperature, then set it to the required equipment, turn on the refrigeration, the compressor will enter the working state, and the machine will start to cool down.
During the use and maintenance process, try to operate according to the requirements. It is not recommended to change the program by yourself to avoid the failure of the high and low temperature cooling circulator. (This article is from the source network, if there is any infringement, please contact Lneya to delete, thank you.)
Raccomandazioni correlate
-
Soluzioni per i guasti degli accessori dell'apparecchiatura di controllo automatico della temperatura del laser a semiconduttore
1762Il compressore di controllo automatico della temperatura del laser a semiconduttori è smerigliato, può essere che la circolazione dell'acqua o la valvola non sia aperta, controllare la valvola dell'acqua, tutte le condutture, per garantire la scorrevolezza, installare una conduttura di cortocircuito. Può essere che la circolazione...
Visualizza dettagli -
Precauzioni per il congelatore a bassissima temperatura
15291. Requisiti dell'ambiente dell'apparecchiatura: Per mantenere l'esterno del frigorifero criogenico pulito e ventilato, è necessario mantenere stabile la posizione orizzontale del frigorifero criogenico e assicurarsi che non ci siano oggetti in giro.2. Mana...
Visualizza dettagli -
The significance of temperature in IC testing
2469Every integrated circuit (IC) goes through two type of tests before it can be sold and used to build a product: the first is called a wafer test; the second is called final test. With the improvement of integrated circuit electrical test technolog...
Visualizza dettagli -
Details of the temperature control system of the isolated reactor
1638The temperature control system of the isolated reactor adopts the heat-conducting medium to perform dynamic temperature control of fluid cooling and heating, and to control the cooling and heating of the heat-conducting medium or the reaction mate...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore