Closed cycle heating system temperature deviation description
If the temperature deviation occurs in the closed cycle heating system during use, it is necessary to check to see if there is any problem in each link, and solve the problem in time.
In the steady state, the closed loop heating system displays the difference between the average value of the temperature and the average measured temperature at the center point of the workspace. (Note: The average display temperature here refers to the average display temperature of the temperature control instrument of the device). In the closed state of the closed circulation heating system (chamber), the measurement points of the working space are measured for the upper and lower deviations of the high temperature and the MIN temperature from the nominal temperature within a prescribed time. The object of the closed cycle heating system is that the temperature control instrument of the device displays the average temperature and evaluates the deviation from the reference point. Obviously, this has nothing to do with temperature uniformity. The closed-loop heating system temperature deviation index is easy to implement because it only evaluates the temperature average of the equipment temperature control meter.
LNEYA closed-loop heating system is dynamic constant temperature control of cold and heat source in high pressure reactor, dynamic constant temperature control of double-layer glass reactor cold and heat source, dynamic constant temperature control of double-layer reactor cold and heat source, and constant temperature of microchannel reactor Control; small thermostatic control system, temperature control of steaming system, low temperature and high temperature aging test of materials, combined chemical source cold source heat source constant temperature control, semiconductor equipment cooling and heating, vacuum chamber cooling and heating constant temperature control. The closed-loop heating system adopts a fully closed pipeline design and uses a high-efficiency plate heat exchanger to reduce the demand for thermal fluid while improving the heat utilization rate of the system and achieving rapid rise and fall temperatures. The heat-conducting medium is in a closed system with an expansion vessel. The heat-conducting medium in the expansion vessel does not participate in the circulation. Whether it is high temperature or low temperature, the temperature of the expansion tank is normal temperature to 60 degrees, which can reduce the absorption and evaporation of the heat-conducting medium during operation. risk.
The temperature deviation of the closed loop heating system is related to its temperature accuracy. The temperature accuracy of different closed loop heating systems is related to the performance of the system. Therefore, users should know how to understand the closed loop heating system at the beginning. Temperature control accuracy. (This article is from the source network, if there is any infringement, please contact LNEYA to delete, thank you.)
Raccomandazioni correlate
-
Come scegliere le apparecchiature di simulazione a bassa e ad alta temperatura per i test di invecchiamento dei materiali?
1736Material aging testing is used in many industries, but how to choose high-quality low-temperature and high-temperature simulation equipment is very critical, because temperature plays an indispensable and important role in the testing process. LNE...
Visualizza dettagli -
Refrigeratore a circolazione per reattore da laboratorio da 100 mL
1219Quando si sceglie il giusto refrigeratore a circolazione per il reattore da laboratorio da 100 mL, ci sono diversi fattori da considerare per garantire che l'apparecchiatura possa fornire un controllo preciso della temperatura e un raffreddamento efficiente. ...
Visualizza dettagli -
Lista di classificazione delle camere di prova ad alta e bassa temperatura con raffreddamento e riscaldamento alternato
1376Nella scelta della camera di prova alternata per il raffreddamento e il riscaldamento ad alta e bassa temperatura, gli utenti dell'impresa devono avere una certa comprensione della graduatoria delle camere di prova alternate per il raffreddamento e il riscaldamento ad alta e bassa temperatura presenti sul mercato...
Visualizza dettagli -
What is the principle of industrial air-cooled chillers
2277Many industrial productions are inseparablefrom the low-temperature production environment provided by the chiller andcannot obtain efficient production capacity. Therefore, industrial chillerequipment is a very important refrigeration equipmen...
Visualizza dettagli