How to deal with the malfunction of Industrial Water Chiller System?
What’s wrong with the Industrial Water Chiller System when it fails to cool down?
Let LNEYA explain it to you below:
One reason is that the initial use of liquid chiller system fails to reduce the temperature, or there is something wrong with the installation of water-cooled chiller, cooling water tower, circulating water pump and pipe. It needs to be carefully checked according to the installation diagram.
The second reason may due to the pipes which are attached to various devices for a long time, and the impurities have accumulated in the water sources, resulting in smaller water flow. Therefore, we must clean the pipes between the devices.
Thirdly, If this problem occurs during the first use, it may cause by the wrong matching of the chiller and the problem of delivery. Because the industrial chiller has carried out 100% performance tests before getting out of the machine to ensure the normal operation of the machine unit.
Finally, If this is the case of a chiller that has been used for half a year or 1-2 years later, it may due to the leakage of Freon in the cooling system of the cold water machine. It is suggested to find out the leakage, weld it again and refrigerant. The heat exchanger of the water-cooled chiller is dirty and needs washing, and remember to clean it regularly after subsequent use.
The operation of any Industrial Water Chiller System is inseparable from the participation of refrigerant. So the shortage of refrigerant will affect the normal operation of the industrial chiller, and then result in the reduction of refrigerating capacity of the industrial chiller and even shut down, which is also the main reason for the shrinkage of the refrigerating capacity of the industrial chiller.
Raccomandazioni correlate
-
Termostato di raffreddamento e riscaldamento per l'esecuzione di test su componenti elettronici
1708If enterprises want the cooling and heating thermostats for electronic component testing to operate for a long time without any faults, they need to achieve the following points to maintain stable equipment performance. 1. Suitable working enviro...
Visualizza dettagli -
What should we pay attention to when purchasing cooling equipment for industrial chiller units?
1342When many customers buy refrigeration equipment for industrial chiller units, they don't know what the key points are. Next, let me talk to you. 1. It should be determined according to the use, refrigerating capacity, local power supply, water sou...
Visualizza dettagli -
-
Descrizione delle prestazioni della camera di prova per gli shock termici
1531La camera di prova a shock termico è ampiamente utilizzata in diversi settori industriali importanti. Al momento dell'acquisto, gli utenti sperano che la loro camera di prova per urti termici possa essere utilizzata a lungo. Pertanto, è necessario comprendere ogni difetto della camera...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore