Characteristic Analysis of Industrial Air Cooled Chiller
Industrial air-cooled chillers are generally integral machines, that is, evaporator, compressor and condenser are made together. For a slightly high-power air-cooled industrial chiller, the heat dissipation of the condenser cooling fan needs to be considered. Since the heat exchange source of air-cooled chiller is air and equipped with special fan, it is called “air-cooled chiller”. It is widely used in medical, biological, chemical, laser, metallurgy, equipment manufacturing, electroplating, plastic processing and other industries.

Working principle of air-cooled industrial chiller: different from the traditional water-cooled chiller, the air-cooled chiller does not need the cooling capacity brought by the cooling tower, so it avoids more investment, and is easy to install and manage. Casters are equipped at the bottom of the chiller, which can be moved to cycle between different working areas. This saves a lot of unnecessary fixed investment, and cold water can be discharged directly by connecting power supply and water pipe. According to the design requirements, the outlet water temperature is generally 2 ℃, 0 ℃, -5 ℃ and -15 ℃. When the temperature is below zero, the refrigerant needs to be mixed for heat exchange. The commonly used refrigerant is ethylene glycol.
Similar to the conventional chiller, the air-cooled chiller also has a fixed refrigeration cycle route. The principle is to use the inverse Carnot effect, which is similar to the current household air conditioner, but the system structure of the refrigeration loop is improved, so the cop (energy efficiency ratio) is often very high.
Characteristics of industrial air-cooled chiller:
1. All pipelines are of thermal insulation design to prevent local convection of machine pipelines.
2. Cooling temperature range: 5 ℃ ~ 35 ℃.
3. The independent temperature controller has anti freezing protection.
4. Stainless steel insulated water tank.
5. Control line phase sequence protection and high and low voltage switch control of refrigerant system.
6. Hydrophilic optical fin condenser has better heat transfer effect and faster heat dissipation.
7. The compressor and pump are provided with overload protection.
8. The shell and tube evaporator with large capacity is adopted, which has good refrigeration effect and can be applied to the environment with high temperature.
9. R404A refrigerant is used, with good refrigeration effect.
10. R507C environment-friendly refrigerant is optional.
Raccomandazioni correlate
-
Performance Characteristics of 30 HP Water Cooled Chiller
1051The 30p water cooled chiller is an industrial water chiller with a horsepower of 30 HP. The water-cooled industrial water chiller must rely on the cooling water tower for work, while the air-cooled industrial water chiller uses its own fan for coo...
Visualizza i dettagli -
How to choose the model of the temperature control device of the lithography machine?
877How to choose a suitable industrial chiller, and what aspects should be paid attention to in the design of the unit?1. Choose air-cooled or water-cooled temperature control device for lithography machineThe condensation methods of industrial chil...
Visualizza i dettagli -
The Structural Characteristics Of Heating Cooling Systems SST-15 SST-20
1012Anyway, Heating Cooling Systems SST-15 SST-20 is a high-performance product with comprehensive functions and simple operation. It will help customers expedite the experiment and save resources so that improve work efficiency.,
Visualizza i dettagli -
ISG/TM Motor Test Cooling System High Voltage Failure and Treatment Measures
1199The ISG/TM motor test cooling system is divided into two types in the industry: air-cooled and water-cooled. The working principle is to first inject a certain amount of water into the water tank in the machine, and then pass the ISG/TM motor test...
Visualizza i dettagli