Application of gas cooling temperature control system in optical module

Il gas cooling temperature control system has a wide range of temperatures and can be widely used to meet the requirements of more production and engineering environments. It is applicable to reliability tests such as chip, microelectronic devices, integrated circuits, small module components, optical communication characteristic analysis, high and low temperature temperature change test, temperature impact test, failure analysis, etc.
In the communication module, due to the continuous increase of the transmission rate, the temperature of the working module will rise to a large extent when the module is working. In order to ensure the normal operation of the module, the temperature reliability test of the communication module needs to be carried out. The traditional verification method is difficult to meet the current test needs due to the slow temperature change, poor stability speed and inability to provide a rapidly changing temperature environment, LNEYA gas cooling temperature control system solves the defects of traditional verification methods and provides fast high and low temperature impact capability as a test method to assist in the production of communication modules.
During the production and quality inspection of communication module, it is required that the product of production module assembly line should be tested within the temperature range. Set different temperature values, simulate the transmission conditions of relevant products, and check whether the automatic frequency adjustment function of components involved in different temperatures is normal. The gas cooling temperature control system can quickly conduct electrical performance test, failure analysis, reliability evaluation, etc.
The gas cooling temperature control system is applied to the high and low temperature test of the optical module. The optical module is an optoelectronic device for photoelectric and electro-optical conversion. The sending end of the optical module converts the electrical signal into the optical signal, and the receiving end converts the optical signal into the electrical signal. The optical module is classified according to the packaging form. The optical module is composed of the transmitter and the receiver. When the transmitter is connected with the receiver through the optical fiber, If the error rate of the whole system does not reach the expected effect, is it the problem of the transmitter or the problem of the receiver? In order to ensure the quality of a finished optical module, it can only be delivered after several steps of testing. The application in the communication field needs to test its receiving and sending function, so it needs to conduct high and low temperature test.
LNEYA gas cooling temperature control system is applicable to accurate temperature control of electronic components. In the manufacturing of semiconductor electronic components used in harsh environments, the IC packaging and assembly, engineering and production testing stages include electronic thermal test and environmental test simulation at other temperatures.
Raccomandazioni correlate
-
How to reduce the cost of semiconductor chip high and low temperature tester?
1031With the rapid development of electronic products, while the quality of products is improving, the decline in product prices is increasingly being valued by consumers. In order to reduce the price of electronic products, it is first necessary to r...
Visualizza i dettagli -
Safety instructions for the use of high temperature circulator heat transfer oil
1117In order to make the high-temperature circulator run more efficiently, it is recommended to pay attention to the safety and choice of the heat-conducting oil. What should be paid attention to the heat-conducting oil of the high-temperature circula...
Visualizza i dettagli -
Precautions for the use of explosion-proof single fluid refrigeration heating temperature control de
994There are many types of reactors, and laboratory reactors are one of them. What is the point of attention of LNEYA reactor temperature control system-explosion-proof single-fluid refrigeration heating temperature control device? The temperature me...
Visualizza i dettagli -
How to avoid operational errors in fluid heat transfer temperature control systems?
971During the operation of the fluid heat transfer temperature control system, if the fluid heat transfer temperature control system fails, the main reason is the operation error. So how do we avoid mistakes. 1. The operation of the fluid heat trans...
Visualizza i dettagli