KRYZ Frequency conversion series
- Capacità di raffreddamento0.5kW~10kW
- Capacità di riscaldamento0.5kW~10kW
- RefrigeranteR134A/R1234yf
- Peso115KG~300KG
Air-cooling & Water-cooling
Dettagli sulla configurazione
Modello | KRYZ-475 KRYZ-475W |
KRYZ-4A15W | KRYZ-4A25W | |
Intervallo di temperatura | -40℃~+100℃ | |||
Precisione del controllo della temperatura | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
Feedback sulla temperatura | Pt100 | Pt100 | Pt100 | |
Display della temperatura | 0.01k | 0.01k | 0.01k | |
Flow output | 1~25 L/min | 1~25 L/min | 1~25 L/min | |
About traffic description | When the temperature is below -30 degrees, the flow rate is controlled within 80% of the maximum value. | |||
Flow control accuracy | ±0.1 L/min | ±0.1 L/min | ±0.1 L/min | |
Pressure display | Using pressure sensor, the pressure is displayed on the touch screen, and the pressure control can be adjusted from 0.2bar to 2.5bar | |||
Heating capacity kW | 7.5 | 15 | 25 | |
Cooling capacity kW | 100℃ | 7.5 | 15 | 25 |
20℃ | 7.5 | 15 | 25 | |
0℃ | 7.5 | 15 | 25 | |
-20℃ | 4.5 | 10 | 16 | |
-35℃ | 1.8 | 4 | 6.5 | |
Compressore | Inverter scroll compressor | |||
Metodo di strozzatura | Valvola di espansione elettronica | |||
Separatore d'olio | Emerson | |||
Filtro essiccatore | Danfoss | |||
Evaporatore | Scambiatore di calore a piastre | |||
Pompa di circolazione | Variable frequency magnetic drive pump | |||
Ingresso, display | 7-inch color touch screen, PLC controller | |||
Programming | 5 programs can be compiled, each program can compile 40 steps | |||
Communications | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet TCP/IP protocol | |||
Protezione della sicurezza | It has self-diagnosis function; refrigerator overload protection; high pressure switch, overload relay, thermal protection device, low liquid level protection, high temperature protection, sensor fault protection and other safety protection functions. | |||
Sistema | The entire system is a fully closed system. There will be no water vapor at high temperatures and no absorption of moisture in the air at low temperatures. The system will not cause pressure to rise due to high temperatures during operation, and will automatically replenish heat transfer media at low temperatures. | |||
Refrigerante | R404A/ R507C | |||
Dimensione dell'interfaccia | G3/4 | G3/4 | G3/4 | |
Water cooled @25℃ | 2500L/H ZG3/4 |
4000L/H ZG1 |
6000L/H DN32 |
|
Condensatore raffreddato ad acqua | The water equipment condenser of this product adopts plate heat exchanger, which requires water supply from chiller or low hardness tap water, and requires water purification filter | |||
Air cooled condenser | Microchannel Heat Exchanger | / | / | |
Power supply 380V50HZ | 14kW | 25kW | 38kW | |
Dimensioni cm | 55*85*175 | 70*100*175 | 80*120*185 | |
Peso | 280 kg | 360 kg | 620 kg | |
Standard | Automatic antifreeze filling system, automatic liquid recovery system | |||
Opzionale | 220V 60HZ three-phase 400V 50HZ three-phase 440V 60HZ three-phase | |||
Opzionale | Temperature extended to -40℃~+135℃ | |||
Osservazione | The external circulation pipeline should have a diameter of DN15 or DN20. The pipeline needs to be well insulated, and high-temperature resistant rubber and plastic insulation pipes can be used. | |||
Materiale della scocca | Cold rolled sheet spraying (standard color 7035) |
Modello | KRYZ-475W/2T | KRYZ-4A15W/2T | KRYZ-4A25W/2T | |
Intervallo di temperatura | -40℃~+100℃ | |||
Precisione del controllo della temperatura | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
Feedback sulla temperatura | Pt100 | Pt100 | Pt100 | |
Display della temperatura | 0.01k | 0.01k | 0.01k | |
Flow output | 1~25 L/min | 1~25 L/min | 1~25 L/min | |
About traffic description | When the temperature is below -30 degrees, the flow rate is controlled within 80% of the maximum value. | |||
Flow control accuracy | ±0.1 L/min | ±0.1 L/min | ±0.1 L/min | |
Fluid output groups | 2 groups | 2 groups | 2 groups | |
Pressure control per group | 0,2bar~2,5bar | 0,2bar~2,5bar | 0,2bar~2,5bar | |
Flow Pressure Description | The device can control flow or pressure independently. Different solutions are required for simultaneous control (customization required) | |||
Heating capacity kW | 7.5*2 | 10*2 | 15*2 | |
Cooling capacity kW | 100℃ | 7.5*2 | 15*2 | 25*2 |
20℃ | 7.5*2 | 15*2 | 25*2 | |
0℃ | 7.5*2 | 15*2 | 25*2 | |
-20℃ | 4.5*2 | 8.5*2 | 14*2 | |
-35℃ | 1.8*2 | 4*2 | 6.5*2 | |
Compressore | Inverter scroll compressor | |||
Metodo di strozzatura | Valvola di espansione elettronica | |||
Separatore d'olio | Emerson | |||
Filtro essiccatore | Danfoss | |||
Evaporatore | Scambiatore di calore a piastre | |||
Pompa di circolazione | Variable frequency magnetic drive pump | |||
Flow rate, pressure | Electromagnetic flowmeter, pressure value 4~20mA | |||
Ingresso, display | 7-inch color touch screen, PLC controller | |||
Communications | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet TCP/IP protocol | |||
Protezione della sicurezza | It has self-diagnosis function; refrigerator overload protection; high pressure switch, overload relay, thermal protection device, low liquid level protection, high temperature protection, sensor fault protection and other safety protection functions. | |||
Sistema | The entire system is a fully closed system. There will be no water vapor at high temperatures and no absorption of moisture in the air at low temperatures. The system will not cause pressure to rise due to high temperatures during operation, and will automatically replenish heat transfer media at low temperatures. | |||
Refrigerante | R404A/R507C/R125/N40 four refrigerants can be used | |||
External output interface size | There are 2 sets of inlet and outlet ports, G3/4 | |||
Water cooled @25℃ | 4000L/H ZG1 |
8000L/H DN32 |
12000L/H DN40 |
|
Condensatore raffreddato ad acqua | The water equipment condenser of this product adopts plate heat exchanger, which requires water supply from chiller or low hardness tap water, and requires water purification filter | |||
Dimensioni cm | 80*120*185 | 100*150*185 | 200*145*205 | |
Power supply 380V50HZ | 28kW | 45kW | 70kW | |
Peso | 660KG | 850 kg | 1350kg | |
Standard | Automatic antifreeze filling system, automatic liquid recovery system | |||
Opzionale | 220V 60HZ three-phase 460V 60HZ three-phase | |||
Opzionale | Temperature extended to -40℃~+135℃ | |||
Osservazione | The external circulation pipeline should have a diameter of DN15 or DN20. The pipeline needs to be well insulated, and high-temperature resistant rubber and plastic insulation pipes can be used. | |||
Materiale della scocca | Cold rolled sheet spraying (standard color 7035) |
Condizioni di prova nominali: temperatura di bulbo secco 20℃; temperatura di bulbo umido 16℃. Temperatura dell'acqua in ingresso 20℃; temperatura dell'acqua in uscita 25℃.
I dati contenuti in questa tabella sono solo di riferimento. Fare riferimento ai parametri della targhetta dell'unità.
Se hai bisogno di personalizzazioni speciali non standard, contattaci.

The equipment can meet the direct cooling/direct heating for battery pack and vehicle testing and testing. This equipment is mainly used for cooling and heating capacity testing. It uses variable frequency compressor with adjustable output; variable frequency fan with adjustable speed and heat dissipation; with high-precision temperature, pressure, flow sensors and built-in software, it can calculate heat exchange capacity in real time, automatically recycle and refill refrigerators, etc. It can meet the needs of battery packs of different sizes.
Potreste essere interessati anche a questi prodotti
Inverter LTZ Serie M
APPLICAZIONI Adatto per l'applicazione all'oggetto di controllo della temperatura target già dotato di un serbatoio di stoccaggio a freddo e di una pompa di circolazione, e il fluido viene trasportato nell'unità di controllo della temperatura di refrigerazione della serie LTZ M attraverso...
LN -60°C~ -10°C
适用范围 Caratteristiche del prodotto 产品参数 Parametro del prodotto 行业应用 APPLICAZIONE 航空航天材料|试验装置控温解决方案 在航空航天领域,材料的性能直接关系到飞行器的安全、可靠性和...
LT -80℃~-20℃
Può garantire un funzionamento continuo per 24 ore Refrigerazione a circolazione di glicole etilenico miscelato con miscela di acqua 1. Può utilizzare glicole etilenico miscelato con acqua per la refrigerazione a circolazione, risparmiando risorse. Può utilizzare glicole etilenico miscelato con acqua per la refrigerazione circolante, risparmiando risorse 2.Cir...
caricamento...