Water chiller for high and low temperature testing of aviation fuel
High and low temperature cooling of aviation fuel usually requires the use of water-cooled chillers rather than air-cooled chillers. This is because water-cooled chillers have higher energy efficiency and better temperature control accuracy, and are more suitable for the cooling needs of aviation fuel.
Application of water chillers in high and low temperature testing of aviation fuel:
Low temperature requirements:
- Fuel freezing point test: used to test the freezing point of aviation fuel at low temperatures to ensure that the fuel will not freeze under cold conditions.
- Low temperature performance test: evaluate the performance parameters such as fluidity and viscosity of aviation fuel under low temperature conditions to ensure that the fuel can be transported and burned normally at low temperatures. In cold areas, the fuel may need to be cooled between -40°C and -50°C.
High temperature requirements:
- Thermal stability test: evaluate the thermal stability of aviation fuel under high temperature conditions to ensure that the fuel will not decompose or produce harmful substances under high temperature conditions.
- Volatility test: test the volatility of the fuel at high temperatures to ensure that the fuel will not volatilize excessively under high temperature conditions. In high temperature areas, the fuel may need to be cooled between 30°C and 40°C.
Temperature Cycle Test:
•Thermal Cycle Performance Test: Simulates the cyclic changes of aviation fuel under different temperature conditions to evaluate the performance stability of the fuel under temperature change conditions. It is usually necessary to control the temperature within the range of ±1°C to ±0.5°C to ensure the stability and safety of the fuel during transportation and storage.
Temperature Variation Range:
•Aviation fuel may experience large temperature changes in different seasons and regions, so the cooling system needs to be able to adapt to a wide temperature variation range. The water chiller needs to be able to operate over a wide temperature range, usually covering a range from extremely low temperatures (such as -60°C) to higher temperatures (such as above 40°C). The ability to quickly switch between high and low temperatures to simulate the rapid temperature changes of aviation fuel under different temperature conditions is very important for evaluating the thermal cycle performance of the fuel.
In summary, water-cooled chillers are more suitable for the high and low temperature cooling needs of aviation fuel due to their high energy efficiency, precise temperature control and stability. When selecting a chiller, it is also necessary to consider factors such as specific application scenarios, cooling requirements, available space, and ease of maintenance.
LN -60°C~ -10°C
适用范围 Caratteristiche del prodotto 产品参数 Parametro del prodotto 行业应用 APPLICAZIONE 航空航天材料|试验装置控温解决方案 在航空航天领域,材料的性能直接关系到飞行器的安全、可靠性和...
LJ -45°C~ -10°C
Raffreddamento rapido e bassa temperatura di raffreddamento -5~-150°C Raffreddamento ad acqua LNEYA è specializzata nella produzione di refrigeratori criogenici monofluido. La temperatura di refrigerazione varia da -150°C a -5°C, in grado di...
LD -80°C~ -30°C
1. Le gamme di temperatura da -5℃ ~ -150℃, possono incontrare la temperatura differente2. Compressore a pistone semi-chiuso di marca famosa, compressore a pistone bipolare semi-chiuso, compressore a vite semi-ermetico, marca principale sono BOCK. Bitzer,...
SLJ -110℃~-150℃
1. Le gamme di temperatura da -5℃ ~ -150℃, possono incontrare la temperatura differente2. Compressore a pistone semi-chiuso di marca famosa, compressore a pistone bipolare semi-chiuso, compressore a vite semi-ermetico, marca principale sono BOCK. Bitzer,...
CDLJ -110°C~ -50°C
Refrigeratore da 5kW; Refrigeratore da 10kW; Refrigeratore da 30kW; Refrigeratore da 60kW; Refrigeratore da 120kW Ampiamente utilizzato nell'industria chimica, farmaceutica, biochimica e in altre industrie nel campo della reazione a bassa temperatura, ...
caricamento...
已经是到最后一篇内容了!
Raccomandazioni correlate
-
Water Distiller Circulating Chiller
758Water distillers generate a lot of heat during operation, especially when they need to run continuously or process a large amount of water. In order to ensure that the water distiller can operate stably and maintain efficient distillation effi...
Visualizza i dettagli -
Serie LTZ a frequenza variabile
3520*Tipo raffreddato ad acqua e ad acqua -115℃~90°C Raffreddamento ad acqua/ad aria LNEYA è specializzata nella produzione di refrigeratori criogenici monofluido. La temperatura di refrigerazione varia da -150°C a -5°C, che può...
Visualizza i dettagli -
How to Select Air Cooled Chiller and Water Cooled Chiller?
581LNEYA offers you free guidance on choosing the right chiller, along with a wide range of air-cooled and water-cooled chillers with different performance options.
Visualizza i dettagli -
Refrigeratori d'acqua e aria a ricircolo a frequenza fissa serie LT
2391APPLICATIONS Zero emission, no pollution, green chiller, create a greener working environment for you.Stable performance capable of working continuously for 24 hours. Product Features Product...