Reactor thermostat heating circulation equipment
Reactor thermostat heating circulation equipment is a kind of equipment used to accurately control the temperature in the reactor during the chemical reaction process to ensure that the chemical reaction can be carried out under the set temperature conditions. This type of equipment usually includes components such as heating system, cooling system, temperature control system, etc., which can provide stable and accurate temperature control.
Main components:
- Heating system, 2. Cooling system, 3. Temperature control system, 4. Circulation system, used to promote the circulation of heating medium or cooling medium between the reactor and the heating/cooling system. 5. Safety protection system, over-temperature protection: when the temperature exceeds the set safety threshold, the heating system is automatically cut off.
Working principle:
1. Heating process:
The heating medium exchanges heat with the material in the reactor, so that the temperature in the reactor gradually increases to the set value.
The PID controller automatically adjusts the power of the heating system according to the difference between the actual temperature in the reactor and the set temperature to keep the temperature stable.
2. Cooling process:
• When the temperature in the reactor needs to be lowered, the cooling medium is transported to the jacket or built-in cooling coil of the reactor through the circulation pump.
•The cooling medium exchanges heat with the material in the reactor, so that the temperature in the reactor gradually decreases to the set value.
•The PID controller automatically adjusts the power of the cooling system according to the difference between the actual temperature in the reactor and the set temperature to keep the temperature stable.
3.Temperature control:
•The temperature sensor continuously monitors the temperature in the reactor and sends a signal to the PID controller. •The PID controller automatically adjusts the power of the heating or cooling system according to the difference between the set temperature and the actual temperature to achieve precise temperature control.
LNEYA’s reactor thermostat heating cycle equipment has high temperature control accuracy: It is usually necessary to control the temperature within the range of ±1°C to ±0.1°C to ensure the accuracy of the reaction process. Heating/cooling rate: It is necessary to be able to heat or cool the materials in the reactor quickly to meet the needs of different chemical reactions. The equipment should have safety measures such as over-temperature protection and pressure protection to ensure safe operation of the equipment. Low noise: The circulation pump and heating/cooling system should reduce noise as much as possible to avoid interference with the laboratory environment. Maintenance convenience: The design should be easy to maintain and clean to ensure long-term stable operation.
COOLING HEATING UNITSfor industrial reaction
Serie di convertitori di frequenza SUNDI Z
WHATSAPP WECHAT La tecnologia di raffreddamento ad altissima temperatura può raffreddare direttamente da una temperatura elevata di 300℃[perché solo il mezzo di trasferimento di calore nell'espansione...
SUNDI -10℃~150℃
Sistema completamente chiuso, singolo mezzo completa la refrigerazione e il riscaldamento -120~350℃ ±0,5℃ AC 380V 50HZ 8kW max La tecnologia di raffreddamento ad altissima temperatura può...
SUNDI -80℃~250℃
● Temperature di lavoro da -120°C a +350°C ● Prestazioni finora irraggiungibili ● Controllo intelligente della temperatura ● Massima stabilità e riproducibilità del processo ● Scambiatore di calore a piastre Adop, riscaldamento a...
SUNDI-320/320W
Sistema completamente chiuso, singolo mezzo completa la refrigerazione e il riscaldamento -120~350℃ ±0,5℃ La tecnologia di raffreddamento ad altissima temperatura può raffreddare direttamente da 300℃ ad alta temperatura. Diventa...
caricamento...
已经是到最后一篇内容了!
Raccomandazioni correlate
-
TOS -45℃~250℃
2180The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it's blocked, then the temperature will go up. A main cause of t...
Visualizza i dettagli -
Sistema di raffreddamento e riscaldamento del bollitore di dissoluzione per cristallizzazione da 200L
820Per le esigenze di 200L cristallizzazione dissoluzione bollitore raffreddamento e riscaldamento applicazioni di sistema, questo tipo di attrezzature è di solito utilizzato nella cristallizzazione, dissoluzione e altri processi nei settori dell'industria chimica, farmaceutica,...
Visualizza i dettagli -
SUNDI -80℃~250℃
2046● Temperature di lavoro da -120°C a +350°C ● Prestazioni finora irraggiungibili ● Controllo intelligente della temperatura ● Massima stabilità e riproducibilità del processo ● Scambiatore di calore a piastre Adop, riscaldamento a...
Visualizza i dettagli -
Sistema di riscaldamento di raffreddamento del reattore per la fabbrica farmaceutica
9651.Process requirements: 2.Media compatibility: 3.Temperature range: 4.Cleanliness requirements: 5.Space and maintenance: In summary, t...
Visualizza i dettagli