A cosa bisogna prestare attenzione quando si installa un sistema di raffreddamento della pila di ricarica CC?

1.Understand the characteristics of the DC charging pile cooling system
Before installing a DC charging pile cooling system, you need to understand the characteristics of the equipment. This includes things like the device’s size, weight, operating temperature range, and power requirements. Ensure that the equipment has sufficient space and power required for its operation at the installation site, and ensure that the operating temperature range of the equipment meets actual requirements.
2.Dealing with common problems of DC charging pile cooling system
During the installation and use of the DC charging pile cooling system, you may encounter some common problems. Here are solutions to common problems:
- Insufficient cooling/heating effect: This may be caused by scaling inside the equipment, blocked pipes, or insufficient refrigerant. Maintenance and maintenance should be carried out regularly, including cleaning internal scale, replacing filters, adding refrigerant and other measures.
- Equipment abnormality: If the equipment has abnormal sound, vibration or odor, it should be shut down immediately for inspection. It may be caused by damaged internal parts of the equipment, broken pipes, or other reasons. The manufacturer or maintenance personnel should be contacted in time for maintenance.
- Electrical failure: If the equipment cannot start normally or other electrical failures occur, you should check whether the power connection is normal and whether the wires are damaged or loose. If you cannot solve it yourself, you should seek help from an electrician.
- Waterway system problems: If the equipment has problems such as water leakage, insufficient water volume, or abnormal water temperature, you should check whether the waterway system is well sealed and whether the accessories are damaged. If you cannot solve it by yourself, you should contact the manufacturer or maintenance personnel for repair.
As a device that can provide both high and low temperature environments, the correct installation and use of the DC charging pile cooling system is crucial to giving full play to its performance. This article will discuss the points to note during the installation of the DC charging pile cooling system.
Refrigeratore a raffreddamento liquido (accumulo di energia commerciale)
Battery Energy Storage Systems are filled with many battery cells, generating a large amount of extreme heat load. This means that the cooling system needs to precisely control the temperature and efficiently dissipate the l…
Refrigeratore di raffreddamento a liquido (pila di caricamento)
Model CHDYL-4 -45℃~55℃ Cooling Power 4KW Temp control accuracy ±1℃ Real-time temperature record Refrigerant Brine circulation system fully enclosed design Flow 1.8~5.5L/min Pressure 0.7bar Minimum water inlet temperature 15°C …
Refrigeratore a raffreddamento liquido (accumulo di energia)
Model CNYL -45~55 Cooling Capacity 45KW Temperature Control Accuracy ±0.5℃ Real-time temperature record Secondary Refrigerant Ethylene glycol antifreeze, fully enclosed design of refrigerant circulation system Refrigerant R41…
caricamento...
已经是到最后一篇内容了!
Raccomandazioni correlate
-
What tests are used by cooling water chillers for new energy enterprises?
914In the process of product development, production and quality control, new energy enterprises will use cooling water chillers to perform a variety of tests. Cooling water chillers play an important role in these tests to ensure the perform...
Visualizza i dettagli -
I test sui veicoli a energia nuova richiedono un refrigeratore o un riscaldatore?
767I test sui motori dei veicoli a energia nuova richiedono sia un refrigeratore che un riscaldatore, poiché i test sui motori coprono un'ampia gamma di condizioni di temperatura per garantire le prestazioni e la stabilità del motore in diverse condizioni operative.
Visualizza i dettagli -
KRY -25℃~+100℃
2297Temperature range is -25℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The equipment can control the flow and pressure independently w...
Visualizza i dettagli -
KRY -40℃~+100℃ (1to3)
2456Dimensioni (A) cm L'intervallo di temperatura è di -40℃~+100℃, che può essere esteso a +135℃ in base alla situazione reale, e la precisione del controllo della temperatura è di più o meno 0,5℃. L'apparecchiatura può controllare il flusso e...
Visualizza i dettagli