Semiconductor production process and testing process temperature control equipment
Use fluid fluorinated liquid for temperature control (minimum -100 degrees)
Gas cold and hot rapid temperature change thermal chuck
Low temperature gas cooler -120 degrees
Direct cooling cooling unit (-150 degrees)
The heating method within 40°C is heated by compressor hot air.
The Chiller ring system adopts a fully enclosed design and a magnetic drive pump.
Chiller100% helium detection, 100% safety inspection, to ensure safety and reliability.
chiller100% after 24 hours of continuous operation copy machine.

Condensatore: micro-channel heat exchanger (air-cooled) plate heat exchanger (water-cooled)
Evaporatore: Plate heat exchanger Throttling device: Electronic expansion valve Circulation system: The whole system is a fully closed system, low temperature does not absorb moisture in the air, does not volatilize heat transfer medium, low temperature automatically replenishes heat transfer medium into the circulation system.
Shell material: cold-rolled plate spray RAL7035
Inside the pipeline: including stainless steel SUS304, copper, ceramics, broken silicon, silicone sealant, PTFE
Control system: PLC programmable controller
Communication protocol: RS485 interface Modbus RTU protocol
Interfaccia Ethernet Protocollo TCP/IP
Operation interface: LNEYA customized 7-inch color touch factory temperature curve display\EXCEL data export
La pompa a frequenza variabile può regolare la pressione e la portata idraulica in circolazione
The output pressure and flow rate of circulating fluid can be set on the operation panel. Even under various customer piping conditions, without bypass piping adjustment, the output pressure can be automatically controlled at the set output pressure through the frequency conversion pump. Thereby, the power consumption of a pump can be reduced. Depending on the flow rate, bypass piping may be required
Circulation heating is possible without a heater because it is heated by the exhausted heat
Raccomandazioni correlate
-
Operation Instructions of Heating Cooling Circulator
949Heating cooling circulator is a process that refrigerant transfers heat from low temperature state to high temperature state, so that its cooling can reach the state of low temperature environment, thus maintaining the low temperature state and re...
Visualizza i dettagli -
Come risolvere la mancanza di capacità di raffreddamento del sistema del ciclo di raffreddamento dei semiconduttori?
1053Il sistema a ciclo di raffreddamento dei semiconduttori è un dispositivo per il raffreddamento della parte riscaldante del semiconduttore nelle apparecchiature di refrigerazione. Viene comunemente utilizzato per testare parti di circuiti integrati a semiconduttore, parti elettroniche di autoveicoli, componenti di fibre ottiche,...
Visualizza i dettagli -
Analysis of the environmental requirements of the -20 °C freezer
1043Due to the difference in ambient temperature, there are certain requirements for the freezer. Today LNEYA came to tell you how the ambient temperature is good for the -20 °C freezer. Now there are many types of freezer boxes: hot and cold temperat...
Visualizza i dettagli -
What equipment is assisted by low-temperature chillers in the pharmaceutical industry?
846The use of low-temperature chillers in the pharmaceutical industry is mainly to meet the strict requirements for temperature control in various production processes, in order to ensure product quality and production safety. Low temperature c...
Visualizza i dettagli