Metodo di ispezione del dispositivo di prova ambientale delle celle a combustibile comuni
During the cooling process of the fuel cell environmental test device, there is a chance of dripping inside. This is not a normal phenomenon used by the fuel cell environmental test device, but is caused by improper installation. After the fuel cell environmental test device is installed, test the machine (refrigeration) immediately. If there is no water leakage after running for a certain period of time, there will be no leakage problem. Of course, the installer can also be required to carry out the water leakage test, and the water is introduced into the internal machine, and the water naturally flows out of the outdoor water through the water receiving tray and the down pipe.
The fuel cell environmental test device will emit a certain amount of noise, but if the noise is too large, it may be caused by improper installation. During the installation, the inner wall panel is not nailed, and the inner machine is not fixedly dead, which may easily lead to excessive noise. In this case, the installer can easily find and correct the problem by testing the machine.
The installation position of the fuel cell environmental test device is also very particular. It is not where the user likes to install it. Otherwise, it will lead to maintenance troubles and poor cooling effect. The households should avoid heavy oil smoke, wind and sand, direct sunlight and heat dissipation. Where there is a poor or high-temperature heat source, it is also necessary to avoid hidden dangers such as flammable gas leaking easily, strong corrosive gas, artificial strong electricity or direct magnetic field action.
If the joint of the fuel cell environmental test device is not tightened, cracked, etc., fluorine leakage may occur. If fluorine is leaking, the user should always replenish it. The normal use of the fuel cell environmental test device generally does not require the addition of refrigerant for several years. The refrigerant leak check should be performed before the test machine. The leak detection is mainly for the four interfaces of the internal and external connecting pipes of the household fuel cell environmental test device and the valve port of the shut-off valve. Soap water (you can also use detergent) leak detection is one of the commonly used methods in the field. After opening the valve for 10 to 15 seconds (the cabinet is 20 to 30 seconds), the valve is closed, and the parts in the system are quickly filled more than A gaseous refrigerant with an air pressure of 0.8 MPa. Apply soapy water to the suspicious point of the leak. If there is a bubble, it will leak. If it is observed for 3 minutes, no bubbles will appear.

The regular installer will check the user’s power supply before installing the fuel cell environmental test device. If the requirements are not met, the user is advised to change it. The power cord is not installed in accordance with the specifications, and it is prone to leakage and fire, which endangers the user’s personal safety. The installer is required to test the power supply with the associated power detection tool.
Since the fuel cell environmental test device has a certain requirement in the fuel cell test, the above faults are avoided as much as possible.
Raccomandazioni correlate
-
Sistema di prova per veicoli a energia nuova ad alta e bassa temperatura
881Con la popolarità dei veicoli a nuova energia, i test ad alta e bassa temperatura sono diventati un fattore che i proprietari di auto devono considerare al momento dell'acquisto. Poiché l'ambiente in cui vengono utilizzati i veicoli a nuova energia è più severo, è anche...
Visualizza i dettagli -
A quali settori possono essere utili i refrigeratori a bassa temperatura?
913Forse alcuni di voi non sanno molto dei prodotti di refrigerazione a bassa temperatura. Il refrigeratore a bassa temperatura è un tipo di apparecchiatura di refrigerazione professionale utilizzata nella produzione industriale. Negli ultimi anni, c'è stata una grande richiesta di diversi tipi di...
Visualizza i dettagli -
Meet in Shanghai World Expo Pavilion 【Pesticide Exhibition】Booth 1G10 10.12-10.14
1271Exhibition name: The 20th National Pesticide Exchange Conference and Agrochemical Products Exhibition HallExhibition time: October 12-14, 2020Booth number: 1G10Exhibition address: Shanghai World Expo Exhibition Hall ,
Visualizza i dettagli -
Development Of LNEYA Low Temperature Chiller
916With the internationalization of the economy, Wuxi Guanya has seized the opportunity. It not only develops rapidly in China, but also actively develops foreign markets, and becomes one of the important enterprises in the development of low tempera...
Visualizza i dettagli