Factors affecting cooling capacity during temperature control of battery test equipment
Battery Test Equipment Refrigeration System The greater the power of the battery test equipment compressor, the higher the cooling capacity. According to the size of the battery test equipment, the compressors of different types are selected. For example, the small battery test equipment is piston type, and the medium type is optional. Scroll type. When the water temperature of the battery test equipment (the evaporation temperature is different, the cooling capacity is different), the higher the cooling capacity, the lower the water temperature, the smaller the cooling capacity. Battery test equipment pump power water circulation amount, directly affects heat transfer speed, evaporator, condenser form, divided into water tank coil test, shell tube type, stainless steel plate type, etc., we need to configure according to certain requirements, thermal material Medium copper tube heat transfer is better.

There are also external factors affecting the cooling capacity of battery test equipment. Most of the battery test equipment is air-cooled. Therefore, the external ambient temperature needs to be within a reasonable range. The condensation temperature should not exceed 45 degrees. Once the cooling capacity is exceeded, it will be significantly weakened. Can not be too low, the battery test equipment air is also very important for convection, the vents can not have a barrier, reference to the standard outlet vents can not have obstacles within 1 meter.
The cooling capacity of the battery test equipment is related to the operation process of the entire battery test equipment. Therefore, the cooling capacity of the battery test equipment must be guaranteed, so that the battery and the motor operate well in the process of cooling and heating.
Raccomandazioni correlate
-
Reasons for the decrease of heat transfer effect of vertical ultra-low temperature refrigerator
1193If the outer frost layer of the vertical ultra-low temperature refrigerator is too thick or excessively dusty, it can be caused because the external temperature of the evaporator is mostly lower than 0 °C, resulting in low heat transfer efficiency...
Visualizza i dettagli -
Minimum 40 degree refrigerator use precautions
1102The temperature of the lower 40 degree refrigerator is indoor temperature: 5-32 °C, relative humidity 80%/22 °C, the distance from the ground > 10cm, the altitude below 2000m, the safe environment guarantees a smoother operation of the lower 40...
Visualizza i dettagli -
Come scegliere il prezzo del sistema a temperatura costante per semiconduttori?
1021Now, it can be said that most of the industrial production of various types require a semiconductor thermostat system to provide professional refrigeration, and an efficient semiconductor constant temperature system can provide great help for vari...
Visualizza i dettagli -
Effetto dello strumento evaporatore per l'esperimento a bassa temperatura sul sistema di refrigerazione
1138In base ai diversi modelli, anche la scelta degli evaporatori per gli strumenti speciali per esperimenti a bassa temperatura è diversa, come gli strumenti speciali per esperimenti a bassa temperatura di tipo box, che utilizzano un evaporatore a serpentina ...
Visualizza i dettagli