Start-up work for new energy thermal management
In the pipeline selection of new energy thermal management, if the use of improper/damaged hoses and/or hose joints will result in injury, the new energy thermal management is limited by the temperature, caliber, installation method, etc. Tube, metal insulation hose temperature range -60 ~ 250 ° C; pressure ≤ 2.5 bar.
When the new energy thermal management configures the metal insulation hose and other pipelines carefully, when referring to its pressure and overpressure capability, caliber and temperature range, consider the lift pressure of the circulating pump inside the equipment. New energy thermal management should choose pipelines with good quality and sufficient volume such as seamless steel pipe as much as possible. The pipeline connection between new energy thermal management and controlled objects should be as short as possible to reduce bending. When the pressure of the new energy thermal management circulation pipeline is too large, the pipeline pressure is insufficient, the pipeline and the reactor will be cracked, and the high temperature and low temperature heat conduction medium may be sprayed, which may cause personnel injury, burns, frostbite and ignition. The possibility of flammable materials, etc.; the pollution caused by the loss of reactants, property damage, and even the possibility of poisoning. The connection of new energy thermal management pipelines should be sealed and firm, with measures such as anti-vibration, grounding, rust prevention and pressure keeping, which can effectively prevent cracks from leaking and corrosion of pipelines;
New energy thermal management The selection of thermal insulation materials should first consider the temperature range of new energy thermal management equipment. It is important to select flame retardant materials. The temperature range of thermal insulation materials should include the temperature range of this new energy thermal management equipment, and have a temperature greater than 30 °C. margin. When the user ignores this problem, there is a possibility of fire. The insulation material package should be sufficient, otherwise the equipment control will not achieve the expected effect.

Other components of the new energy thermal management pipeline include valve components, gaskets, pressure gauges, cooling towers, cooling water pumps, etc. In order to ensure the stable operation of new energy thermal management equipment, the temperature range, pressure range and use of these components should be fully considered. Environment, use media, power and other parameters.
The management of new energy thermal management equipment should be carefully read the corresponding instructions, and then detailed preparations should be made before the corresponding preparations.
Raccomandazioni correlate
-
The Importance of Electric Vehicle Battery Testing Chillers
990The Importance of Electric Vehicle Battery Testing Chillers
Visualizza i dettagli -
Protection device details of circulating fluid temperature control device
1132The circulating pump overload protection function is to cut off the main power of the circulating pump when the circulating liquid temperature adjustment device is too large. Press the green button when resetting; the red button is the stop button...
Visualizza i dettagli -
Why does a chiller need to be installed for cooling the water storage tank?
977The main reasons for configuring a chiller for cooling the water storage tank are related to the following aspects: Temperature Control: In many industrial and commercial applications, such as air conditioning systems, chemical processes, ...
Visualizza i dettagli -
What are the advantages and disadvantages of thermal oil heating circulators?
1197The heat conduction oil heating circulator adopts a fully closed loop structure to directly act on the heat energy to the heated medium.Its advantages are: (1) Due to the continuous renewal of the heat transfer surface, the heat loss is small; (2...
Visualizza i dettagli