How to install -50 °C cryogenic unit manufacturers equipment?
-50 °C cryogenic units are used in the refrigeration and chemical industry, so what issues should be paid attention to during installation? LNEYA professional manufacturers tell you that you should install according to the instruction manual.
For the -50 °C cryogenic unit compressor (unit) that has been tested at the factory and is protected by rust-proof seals and has good pre-installation protection measures, it can be directly installed, the protection measures are invalid, or the compressor (unit) has obvious defects. Check it and install it after confirming that it meets the factory manufacturer’s factory standards.
-50 °C cryogenic unit compressor (unit) should check the position of the foundation and anchor bolt holes before it is in place, it should meet the requirements of the design documents; it should be installed in the foundation and bracket according to the connection method required by the design and equipment technical documents. Welding shall not be used on hangers and on the design and equipment technical documentation. The installation should meet the requirements of the equipment technical documents. When leveling is required, the horn should be used. The installation should keep the body stable and should not exceed the inclination angle of the technical documentation of the equipment. Do not invert.
-50 °C cryogenic unit compressor (unit) manufacturer to ensure that the compressor does not corrode after leaving the factory and before use, no impurities, more inert gas for sealing treatment, so as long as the seal is intact, no obvious defects can be directly installation. For small, lightweight-50-degree cryogenic unit compressors (units), manual handling can be carried out during the installation process. Due to exceeding the limit angle or inversion, internal irreparable damage may occur, so standard handling is required. Refrigeration auxiliary equipment such as intercooler, gas-liquid separator, oil separator, liquid receiver, low-pressure circulating reservoir, oil collector, chiller, condenser, etc. in the refrigeration system shall be installed in accordance with current standards.
-50 °C cryogenic unit manufacturer Wuxi Guanya (LNEYA) will be arranged at the factory, the corresponding instructions to follow the equipment, the user can install according to the instructions.

Raccomandazioni correlate
-
L'analisi del prezzo del congelatore ultra basso
1179Quali sono le caratteristiche e le funzioni del congelatore ultra basso: 1. Il congelatore ultra basso può impedire che la precisione delle apparecchiature della macchina sia influenzata dalla variazione della temperatura dell'olio durante il funzionamento. 2. Il congelatore ultra basso può prevenire...
Visualizza i dettagli -
Classification and Application of Industrial Water Chillers
1221In lots ofindustrial production processes, it is difficult to obtain high efficientindustrial production efficiency if there is no industrial water chiller toprovide a low temperature production environment. Therefore, industrial water chill...
Visualizza i dettagli -
What to do When the High Pressure Alarm of the Chiller?
1281People must pay attention to the maintenance of large-scale temperature control equipment such as industrial water chiller. Sometimes it is normal to encounter high-pressure alarm. We must first find out the causes of high-pressure of the industri...
Visualizza i dettagli -
Introduzione all'uso del refrigeratore di precisione a prova di esplosione
1115Wuxi Lneya solves the problem of how to charge refrigerants in the absence of refrigeration. 1. Connect all kinds of equipment well, close the three valve when the vacuum pressure is down to 133.3Pa, remove the hose from the suction port of the va...
Visualizza i dettagli