Temperature cycle failure analysis of single fluid heating refrigeration system
The performance of single-fluid heating and cooling systems of different manufacturers is different. LNEYA is committed to creating a high-configuration single-fluid heating and cooling system to solve the problem of cooling and heating temperature control for users. How to solve the problem of temperature cycle failure in single-fluid heating and cooling system? ?
The basic parameters of the temperature cycling of the single-fluid heating and cooling system are mainly six: 1 upper limit temperature; 2 lower limit temperature; 3 temperature change rate; 4 upper limit temperature holding time; 5 lower limit temperature holding time; In the single-fluid heating refrigeration system temperature cycle test, the uniformity of the gas flow in a single-fluid heating refrigeration system is an important parameter that will affect the temperature change rate of the product. The mechanism and sensitive components of temperature cycle induced failure: temperature cycling makes different materials with different expansion coefficients expand differently, causing peeling, cracking, and sensitive components such as paint coating.
The temperature cycling of the single-fluid heating and cooling system makes the joints that are screwed or riveted loose, and the sensitive components such as screws and riveted parts; the temperature cycle makes the press-fit joints with insufficient mechanical tension slack; the high-low temperature alternating test chamber temperature cycles make the material Poor solder contact resistance increases or induces an open circuit, and its sensitive components such as resistive components; temperature cycling causes contact corrosion and contamination, and its sensitive components such as alloy materials.
Therefore, for the user, the high-performance configuration of the single-fluid heating and cooling system is very important, the cheap single-fluid heating and cooling system is not necessarily easy to use, and the expensive single-fluid heating and cooling system will not go wrong. (This article is from the source network, if there is any infringement, please contact LNEYA to delete, thank you.)
Raccomandazioni correlate
-
What are the noise reduction methods for industrial chillers?
963Question: What are the noise reduction methods for industrial chilled water machines? Answer: 1. Industrial industrial chilled water machine axial fan has different noise due to different wings and speed. The noise of octopole electromechanical is...
Visualizza i dettagli -
Maintenance for Lubrication System of Water Cooled Chiller Plant
984Medium-sized low-temperature freezer, refrigeration temperature range from -80 ℃ ~ -30℃, safe, reliable, rapid cooling for the liquid, widely used in petrochemical, medical, pharmaceutical, biochemical and freeze-dried, military and other high-tec...
Visualizza i dettagli -
Analysis of the work and industry application of the chiller
1038Although there are many different types of chillers, most use the same cooling principle. An important part of the process is the coolant or refrigerant, which holds more heat than water and helps maintain an efficient cooling process. Heat is rem...
Visualizza i dettagli -
Application area of high temperature refrigeration and cooling control system
850The high-temperature refrigeration and cooling control system is used for supporting glass reactors, rotary evaporators, fermentation tanks, and calorimeters; widely used in petroleum, chemical, metallurgical, biochemical, physics, testing and che...
Visualizza i dettagli