Application area of high temperature refrigeration and cooling control system
The high-temperature refrigeration and cooling control system is used for supporting glass reactors, rotary evaporators, fermentation tanks, and calorimeters; widely used in petroleum, chemical, metallurgical, biochemical, physics, testing and chemical analysis research departments, universities, and factory experiments Laboratory and metrology quality inspection department. The high-temperature refrigeration and cooling control system can provide cooling circulating water to cool the equipment or provide heat for heating according to the production requirements, and at the same time, the temperature can be kept constant between ±2°C.
The high-temperature refrigeration and cooling control system can be used for heating and cooling, and can also realize mutual switching to speed up production progress and reduce energy consumption, improve product molding efficiency, and reduce the production of defective products. Computer touch control, automatic calculation model, multi-point temperature control unit can be customized. The temperature can be automatically controlled, and the set temperature can be reached quickly, and the set value and actual value are displayed separately. Isolated electrical control box, extend the service life of electrical appliances, pipeline explosion-proof device, built-in safety protection, low noise, high temperature and corrosion resistance, unique heating design, power saving and durable, suitable for use in different temperature control places.
The high-temperature refrigeration control system is a laboratory instrument with dual functions of heating and cooling. This instrument adopts a number of proprietary technologies and has high temperature control accuracy. It is mainly used in biological, chemical and other fields (such as rotary evaporators, reactors, fermentation tanks) , Calorimeter and other equipment); this instrument is highly automated and can automatically heat or cool according to set requirements; this type of temperature control equipment has universal heating and cooling functions and can meet the needs of various biochemical experiments.
The design and component parts of the refrigeration circuit of the high temperature refrigeration and cooling control system are particularly important for the control of the mold temperature. When the temperature of the mold or heating fluid rises to the set value, it can quickly and effectively prevent the temperature from continuing to rise. Therefore, according to different customers, the instructions are different, because it can be customized according to the needs of different customers.
Raccomandazioni correlate
-
Quali riferimenti sono necessari per la scelta del sistema di controllo della temperatura del reattore?
1612La selezione della potenza di riscaldamento del sistema di controllo della temperatura del reattore si basa approssimativamente sulle dimensioni del reattore. Il sistema di controllo della temperatura del reattore è un dispositivo a temperatura costante utilizzato per riscaldare e raffreddare il reattore. Al momento della selezione, i due ...
Visualizza dettagli -
Il motivo dell'esistenza del frigorifero criogenico nell'industria della produzione di parti di utensili
1366Il trattamento criogenico viene applicato agli utensili usurati, ai materiali delle fustelle e successivamente esteso agli acciai legati, al carburo cementato, ecc. Questo metodo è in grado di modificare la struttura interna dei materiali metallici, migliorando così la meccanica e la lavorazione...
Visualizza dettagli -
What is the refrigerant of the recirculating chiller
1683Different industries have differentrequirements for the refrigeration temperature of the recirculation chiller, sothe selected refrigerant is also different. When choosing a recirculationchiller, it is also necessary to have a clear understandi...
Visualizza dettagli -
Quali sono i metodi di riduzione del rumore per i refrigeratori industriali?
1546Domanda: Quali sono i metodi di riduzione del rumore per le macchine industriali ad acqua refrigerata? Risposta: 1. Il ventilatore assiale delle macchine industriali per l'acqua refrigerata ha un rumore diverso a causa delle diverse ali e velocità. Il rumore dell'octopolo elettromeccanico è...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore