The Use of Electronic Expansion Valve in Low Temperature Chiller Systems
In the low temperature chiller system, the electronic expansion valve plays a key role in controlling the operating power of the system in cooperation with compressors, condensers, evaporators, water-cooled screw chillers, air-cooled screw chillers, cryogenic screw chillers, central air-conditioning units, chillers, water-cooled chillers and air-cooled chillers. Its operation situation will determine the practical refrigeration ability and control accuracy of the low temperature chiller system. However, most chillers use electronic expansion valves or thermal expansion valves as a saving arrangement of system. Controlling the superheat of the compressor inlet is most primary. However, due to the positioning in this planning, the electronic expansion valve can not fully exert the control efficacy of system accuracy. During the operation of low temperature chiller system, control can complete the optimal output control of system cooling capacity, but as is always the case, it can’t be completely exerted to output control system cooling capacity when the temperature is close to the equipment policy. the accuracy of the system can’t be ensured. Although the precision has been improved when using the method of PID control, as a whole, there is still a lot of room for improvement.
Equipment and Planning of Electronic Expansion Valve
In the low temperature chiller system, the electronic expansion valve is generally used as a general saving arrangement to control the superheat of compressor. It is usually equipped between the evaporator inlet and the condenser outlet. According to the superheat of compressor inlet, the size of the adjustable opening is analyzed and judged in real time, and the optimal control of superheat is completed to reach the optimal output of system cooling capacity. However, when the control needs to be accurate , due to the constraints of superheat, the best ability of refrigeration output control is often not brought into play, and the system temperature control accuracy is poor.
Raccomandazioni correlate
-
What are the causes of the blockage of the cooler?
975The LNEYA Chiller Cooler HRT whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical conn...
Visualizza i dettagli -
What are the noise reduction methods for industrial chillers?
961Question: What are the noise reduction methods for industrial chilled water machines? Answer: 1. Industrial industrial chilled water machine axial fan has different noise due to different wings and speed. The noise of octopole electromechanical is...
Visualizza i dettagli -
A cosa bisogna prestare attenzione quando si aggiunge refrigerante a un refrigeratore raffreddato ad acqua
1123Nella nostra vita, crediamo che tutti abbiano molta familiarità con la refrigerazione. Nel settore della climatizzazione centrale e dei processi di raffreddamento della produzione industriale, i piccoli refrigeratori raffreddati ad acqua sono più comuni. Questa unità è composta da un compressore...
Visualizza i dettagli -
API exhibition LNEYA is brilliant
1195On October 14, 2020, the 85th China International Pharmaceutical Raw Materials/Intermediates/Packaging/Equipment Fair (API China for short) was grandly opened at Nanjing International Expo Center. The exhibition site was bustling and popular. LNEY...
Visualizza i dettagli