Classification and advantages and disadvantages of water-cooled chillers
Industrial chillers are divided into air-cooled industrial chillers and water-cooled industrial chillers. Today we will discuss the classification, advantages and disadvantages of water-cooled chillers.
Advantages of water-cooled chillers:
1. Intelligent control data changes in one second to understand the color touch screen to display the set temperature and measured temperature, 7-inch touch screen operation, sensitive touch, simple and quick operation, dynamic display of unit operation.
2. Dynamic monitoring makes dynamics nowhere to escape, dynamic monitoring operation automatically displays the working status of compressors, water pumps, etc., the status of the unit is clear at a glance and is under control.
3. Self-diagnosis is more than intimate, self-diagnosis powerful self-diagnosis function makes it easy for you to diagnose faults.
4. The condensing control is so stable, the condensing temperature control intelligently controls the condensing temperature, high efficiency and energy saving, to ensure the continuous and stable operation of the compressor.
5. Intelligent antifreeze function When the water temperature is low, the unit will automatically enter the antifreeze mode, so there is no need to worry about the unit being damaged by freezing

Water-cooled chiller configuration:
1. Compressor
Selected from Emerson and other original imported ming brand compressors. It has the advantages of stable and reliable operation, high efficiency, low failure, good performance, low vibration and low noise, energy saving, convenient maintenance, and long life. According to customer needs and the size of the cold tonnage, a single machine or a combination of multiple machines is used. The compressor can automatically alternate operation according to load changes, automatic energy adjustment, balance the operating hours of each compressor, and greatly extend the service life of the chiller.
2. Condenser
It uses copper pipes imported from abroad to be processed into trapezoidal low-rib pipes to enhance heat transfer capacity. The surface of the copper pipe is smooth, which reduces the water pressure and is easy to clean and maintain.
3. Protective device
The protection devices of water-cooled chillers include: compressor delay start protector, overload protector, high and low pressure protector, temperature control switch, antifreeze switch, fuse plug, electronic time protection an full valve, compressor overheat protector, compressor Start the protector and abnormal indicator frequently to ensure the normal operation of the unit.
4. Intelligent computer control system
The high-intelligence PLC and PC-level computer control system can be used for remote monitoring and control. It has multiple functions such as automatic loading and unloading, timing power on and off, and recording the cause of failure. The operation is simple, and the host is connected to the power supply. The failure rate is low, the an overall factor is high, the installation is simple, the system control can be adjusted in real time, and it is intuitive and reliable.
5. Freezing accessories
Refrigeration accessories are all selected from the world’s leading brand, the performance is more and more environmentally friendly. For circuit breakers and contactors, select Danfoss brands such as Schneider brand, expansion valve, filter drier, etc.
Disadvantages of water-cooled system:
For the open-type cooling water system, as the cooling water absorbs heat and contacts with the air, CO2 escapes into the air, and the dissolved oxygen and turbidity in the water increase, causing the cooling water system to have 4 major problems: corrosion, scaling, The growth of bacteria and sludge. If the water quality is not treated, it will seriously damage the refrigeration equipment, greatly reduce the heat exchange efficiency, and cause a waste of energy. Therefore, it is very important to carry out corrosion inhibition, scale inhibition, and algae-killing treatments for the system water.
Advantages of water-cooled chillers: relatively larger cooling capacity, lower noise, and lower price
to sum up
The water-cooled industrial chillers produced by LNEYA can be customized for equipment power, size and temperature range.
Raccomandazioni correlate
-
Istruzioni per l'uso del refrigeratore criogenico industriale
1171I frigoriferi industriali sono una delle macchine ad acqua fredda. Sono classificati in base alla modalità di raffreddamento della macchina ad acqua fredda stessa. Si dividono in frigoriferi con raffreddamento ad aria e frigoriferi con raffreddamento ad acqua. Caratteristiche strutturali: un ...
Visualizza i dettagli -
Precautions for cooling and heating during operation of various reactors
893In many laboratories, various reaction vessels of chemical companies are indispensable reaction vessels, and its operating temperature: -80°C-250°C. The laboratory reactor works at normal temperature, and cooling water must be passed normally to a...
Visualizza i dettagli -
Detailed Operating Instructions of Industrial Chiller
1333The installation procedures of waterchiller include:1. During installation, please checkwhether the machine is damaged and select a suitable place for installation andfuture maintenance. The site for installing the unit must be the floor or...
Visualizza i dettagli -
Descrizione del compressore del dispositivo di prova del calore umido ad alta e bassa temperatura
1235I diversi tipi di compressori per i dispositivi di prova del calore umido ad alta e bassa temperatura hanno spesso un impatto sul prezzo. Al momento della scelta, dovremmo scegliere compressori di refrigerazione a basso consumo energetico il più possibile. Ora la Cina sta prestando sempre più attenzione...
Visualizza i dettagli