Risoluzione dei guasti alle ventole del sistema di raffreddamento del gruppo motore
The fan is generally installed at the upper end of the cooling system of the engine powertrain, and some customers choose to install it on the side according to regulations. For screw chillers that use fans to dissipate heat, they are called air-cooled screw chillers. The natural environment for installation must be wide and the gas is easy to circulate, so that it will not easily harm the air-cooled screw chillers. The actual cooling effect.
As for those belonging to mechanical equipment, there will undoubtedly be some common faults during the whole process of installation or application. So, what are the common problems with the fans of air-cooled screw chillers? How should the company clear it?
1. The noise of the air-cooled screw chiller is too loud:
1. The bearing component is worn out/excessive gap: if it is worn out, it should be dismantled and replaced immediately, if the gap is too large, it can be adjusted to a suitable position immediately;
2. The speed ratio is too high: it can be improved by reducing the speed ratio. If it has not been processed, the fan should be removed and replaced;
2. The temperature of the motor of the air-cooled screw chiller fan is too high:
1. The total flow exceeds the rated current: the gate valve can be adjusted at this time;
2, what is the problem with the motor or switching power supply level: search for the reason for the motor and switching power supply level;
3. The temperature of the bearing of the air-cooled screw chiller fan is too high:
1. Insufficient grease (grease) or poor quality: If insufficient grease is added, the company should fill the oil to the required position; if the quality is poor, the bearing should be cleaned and then replaced with the grease that meets the standard (fat);
2. The fan shaft and the motor shaft are not the same: they should be adjusted in the same boat;
3. The bearing is damaged: At this time, a new bearing should be disassembled, or the chiller manufacturer should be contacted immediately for dismantling and replacement;
4. The exhaust air volume of the air-cooled screw chiller fan is too small:
1. Check whether the rotation direction of the centrifugal impeller is reversed. This can be dealt with by replacing the position of the two wires of the motor at will;
2. Insufficient opening degree of the gate valve, too loose transmission belt and insufficient speed ratio: It can already be enlarged to a suitable opening degree according to the adjustment gate valve, tightening or dismantling the transmission belt, and checking the working voltage to check the bearing;
3. Blockage of the air supply or vents and pipes: check the air supply/vents and eliminate the blockages;
4. It may be that the connection between the centrifugal impeller and the shaft is loose, which can be removed by tightening immediately; if the gap between the centrifugal impeller and the air inlet is too large, it should be adjusted to a suitable gap.
The fan of the air-cooled screw chiller is equivalent to the closed cooling tower refrigeration system of the water-cooled chiller. If the actual effect of heat removal is not good, then the air-conditioning capacity of the air-cooled screw chiller is definitely not enough, which will immediately harm the company Requirements for refrigerated water. Therefore, it is very necessary to carry out timely inspection, maintenance, and maintenance of air-cooled screw chillers, which can not only reduce the equipment failure rate of air-cooled screw chillers, but also help increase the service life of air-cooled screw chillers.
Raccomandazioni correlate
-
Reactor thermostat heating circulation equipment
746Reactor thermostat heating circulation equipment is a kind of equipment used to accurately control the temperature in the reactor during the chemical reaction process to ensure that the chemical reaction can be carried out under the set te...
Visualizza i dettagli -
Won the second place in the 2022
1517On November 18, 2022, it was sponsored by the Jiangsu Provincial Association for Science and Technology, the Provincial Taiwan Affairs Office, the Provincial Department of Industry and Information Technology, the Provincial Department of Agricultu...
Visualizza i dettagli -
LED LCD display thermal test system operation process
928The integrated semiconductor industry has developed rapidly in the past two years, which has driven other industries around it. The chip thermal test system is one of the products. In order to avoid machine failures in the LED liquid crystal displ...
Visualizza i dettagli -
The Method That Small Water Cooled Chiller Needs To Follow When Charging Refrigerant
1119Nella nostra vita, crediamo che tutti abbiano molta familiarità con la refrigerazione. Nel settore della climatizzazione centrale e dei processi di raffreddamento della produzione industriale, i piccoli refrigeratori raffreddati ad acqua sono più comuni. Questa unità è composta da un compressore...
Visualizza i dettagli