Applicazione e principio di funzionamento del refrigeratore ad acqua
Application and working principle of
water-cooled chiller
The water-cooled chiller is a kind of LNEYA
industrial low-temperature refrigerator in Wuxi Guanya. A single compressor can
achieve -152 degrees Celsius cooling and cooling. Equipment power, size and
temperature range can be customized.
1. Application
Refrigerators are widely used in industrial
machinery processing, industrial cold processing assembly, petrochemical, fine
chemical, and other high-tech industries.
2. Working principle
The gas-phase refrigerant is compressed
into a high-temperature and high-pressure gas in the compressor, and then
enters the condenser, where the refrigerant releases heat and condenses into a
liquid. After the high-pressure liquid refrigerant is dewatered by the dryer,
it passes through the expansion valve to save pressure and turns into
low-pressure wet vapor, and then enters the evaporator to absorb heat and
vaporize into low-pressure gas. The low-pressure gas enters the compressor to
form a cycle. It can be seen that the reasons affecting the refrigerator are
related to the compressor, condenser, expansion valve and evaporator, and in
the refrigerant cycle, the oil-water separator is also a factor that affects
the refrigeration effect. Let’s do a brief analysis below. If the refrigerating
unit is running and the inlet pressure is low and the equipment shuts down, if
the amount of refrigerant is sufficient, the expansion valve will be blocked or
frozen and the refrigerant will not enter the evaporator smoothly, and the
inlet pressure will be low and an alarm will be shut down. And by checking
whether there are impurities in the filter element of the dryer, it can be
judged whether it is a fault of the expansion valve.
Product advantages of water-cooled chillers
1. Safety protection devices: Schneider and
other well-known brand leakage circuit breakers, phase sequence open phase
protectors, liquid level protectors, high and low voltage protectors, high
temperature protectors and other safety protection devices
2. Intelligent computer control system:
Siemens LCD display, display set temperature and control temperature, data
communication interface, USB data export, Ethernet interface, etc.
3. International brand imported
accessories: a full set of imported cold controls, international brand
compressors and circulating pumps, to meet continuous high and low temperature
continuous work, and protect the system from damage
4. Support customization: support
customization, size and pressure customization can be made according to working
conditions, positive pressure explosion-proof and isolation explosion-proof can
be customized, and it can be widely used in dangerous explosive places.
Riassumere
LNEYA focuses on the production of
water-cooled chillers, which can be customized according to working conditions.
Global consulting sales@lneya.com
Raccomandazioni correlate
-
Qual è il principio di refrigerazione del sistema di refrigerazione a glicole?
1226Il sistema di refrigerazione a glicole, come si evince dal nome, consiste nell'utilizzare il glicole come agente refrigerante per il refrigeratore. Nell'ambiente a tutt'aria, a causa della bassa temperatura esterna, è impossibile utilizzare una torre di raffreddamento per l'alimentazione...
Visualizza i dettagli -
Diversi aspetti di attenzione del congelatore a bassissima temperatura
1219Le prestazioni dei congelatori a bassissima temperatura si riducono naturalmente a causa dell'applicazione prolungata in tutti i campi. Pertanto, Guanya Refrigeration Technology Co., Ltd, leader nella produzione di congelatori a bassissima temperatura, ricorda a tutti gli utenti...
Visualizza i dettagli -
Explosion-proof high and low temperature one machine evaporator use note
1064Each accessory in the explosion-proof high and low temperature integrated machine is more important. Among them, the evaporator has one of the four major accessories, and the refrigeration effect has a certain degree. What are the main choices of ...
Visualizza i dettagli -
How to use multiple reactors for high and low temperature integrated machine
1367Multiple reactors high and low temperature integrated machine temperature control system will be connected with thermal conductive synthetic oil and power supply before use, and multiple reactor high and low temperature integrated machine temperat...
Visualizza i dettagli