Qual è il principio di refrigerazione del sistema di refrigerazione a glicole?
Glycol Chiller System , as we can tell from
its name, it is to use Glycol as the refrigeration agent for the chiller.
In the all air environment, because of the
low temperature in the outdoors, it is impossible to use a cooling tower to
supply the inner area directly with the cold air-conditioner. In addition, the
cold air in the outdoors could be used directly as refrigerator source,with glycol
as refrigerant, it can introduce the natural cold air into the inner area and
supply cold air-conditioner. If we need to heat the outer area and provide
cooling for the inner area, we can turn off the chiller and Boiler or
industrial hot water is still used as heat source for external heating.
Install plate heat exchanger in the
outdoor, and the outdoor cold air is introduced into the plate heat exchanger
by the fan. The glycol solution and the outdoor cold air are exchanged in the
plate heat exchanger. The cooled glycol solution enters into the air
conditioners in the inner area and exchange with mixed air. Then the mixed air
enters into the inner room with lower temperature and supply cooling. The
temperature of glycol solution rise up, it comes back to the plant heat
exchanger in the outdoor again, exchange heat with the cold air in the outdoor
and continue this cycling after the temperature is lowered. This way of heat exchange is usually used in
the heat recycling system.
It is a very energy-saving way that use
glycol as a refrigerant to introduce the cold air in the outdoors to supply
cooling for the inner area. All we need to do is to install a heat exchanger in
the outdoor.when it works, the cold water equipment closed, opening the fan and
the glycol chiller can bring cooling for the inner area. In this way, we can
save energy and reduce the cost.
Our LNEYA self-developed low-temperature
refrigeration circulator, also known as the glycol chiller, has a cooling
temperature range from -125°C to -20°C, using a computer cascade temperature controller and a PT100
temperature sensor. The product adopts ethylene glycol and water mixture for
circulating refrigeration to save water resources; adopts supercooling
technology to ensure temperature stability at low temperatures; adopts a fully
enclosed design to ensure the purity of the cold heat transfer medium, prevent ice
crystals, and increase the life of the heat transfer fluid. There are two
temperature series, LX and LT, to meet the low temperature control requirements
of chemical and pharmaceutical low temperature reactions. You can contact us to
obtain the detailed parameters of the temperature range you need.
Raccomandazioni correlate
-
Transmission powertrain cooling system with evaporator
954The evaporator is one of the four major components of the refrigeration system, and it is the ultimate embodiment of the refrigeration effect and efficiency. The evaporator is generally designed and equipped by the transmission powertrain cooling ...
Visualizza i dettagli -
Qual è la ragione per cui il sistema di refrigerazione industriale non può essere raffreddato
1228Let the LNEYA technical engineer explainthe reason for everyone: The first one: The chiller system fails tolower the temperature during the first use, or there is a problem with theinstallation of the industrial water chiller, cooling tower, ...
Visualizza i dettagli -
Come scegliere un refrigeratore di idrogeno?
833Il refrigeratore (chiamato anche sistema di raffreddamento o chiller) nel processo di produzione dell'idrogeno è uno dei componenti chiave per garantire il funzionamento stabile delle apparecchiature di produzione dell'idrogeno. Il refrigeratore aiuta a mantenere l'elettrolizzatore, il reattore e...
Visualizza i dettagli -
New energy vehicle testing comprehensive test box filled with heat transfer oil
1260In order to ensure the correct operation of the machine, the new energy vehicle inspection integrated test box must ensure that no air bubbles remain in the system, ensure that the heat transfer medium outlet is connected to the lower interface of...
Visualizza i dettagli