Characteristics and Advantages of Air Cooled Chillers
1. Configuration of air-cooled chiller
Air cooled chillers can be divided into air-cooled vortex chillers and air-cooled screw chillers according to the type of compressor. The air-cooled vortex chiller is mainly composed of vortex compressor, evaporator, condenser, refrigeration element, circulating water pump, stainless steel water tank and original imported fan electric control system. The air-cooled screw chiller is composed of screw compressor, evaporator, condenser, refrigeration components, imported fan and electric control system. All the above parts are guaranteed to be 100% new and original. Welcome new and old customers to our factory for on-site inspection.
2. Protective device of air-cooled chiller
Long service time or improper operation of air-cooled chiller will cause unit failure. In order to ensure the safe and stable operation of chiller, the equipment itself is equipped with multiple safety protection devices, such as reverse phase protection device, compressor overload protection device, high and low pressure protection device, automatic alarm device, low temperature anti icing protection device, etc. Even if the chiller fails, the protection device can be started at the first time to avoid secondary injury to the chiller.
3. Temperature control of air-cooled chiller
Both air-cooled box chillers and air-cooled stacked rod chillers can meet the refrigeration temperature required by various industries, up to 350 ℃ and down to – 150 ℃. Moreover, the temperature adjustment can be set on the control panel of the chiller according to the demand. The specific setting method can be in accordance with the operation manual of the chiller.
4. Energy saving and environmental protection of air-cooled chiller
Chillers belong to mechanical equipment, and the primary problem considered by users is power consumption. One feature of air-cooled chiller is that after reaching the refrigeration temperature required by users, the compressor stops running to save electric energy. When the temperature is higher than the temperature set by the user, the compressor will restart to save power consumption for the user to a certain extent. In addition, for chillers with multiple compressors, each compressor has an independent refrigeration system. Users can decide the number of compressors to be started according to production needs, which is more flexible and convenient to use.
Raccomandazioni correlate
-
Necessity of temperature control in fractional distillation of distillation
954The pharmaceutical and chemical industry involves many chemical reactions, and with the continuous development of the pharmaceutical and chemical industry, there is a great demand for such instruments. The traditional open cooling and heating con...
Visualizza i dettagli -
Main points of maintenance of LNEYA ultra-low temperature refrigeration circulator
1085Ultra-low temperature refrigeration circulators need to be maintained after a long period of operation, so what aspects should be paid attention to? Check and maintain the ultra-low temperature refrigeration circulator on time. It can find problem...
Visualizza i dettagli -
How to eliminate the failure of large thermal shock test chamber?
985As technology continues to advance and improve, LNEYA recommends strict requirements for operators of large thermal shock test chambers. If used improperly, operators need to be able to face and resolve these problems in a timely manner. A large t...
Visualizza i dettagli -
The relationship between vocs adsorption condensing equipment price and configuration
951The quality of vocs adsorption condensing equipment must be guaranteed. This can be used with confidence. The reason for the power consumption may also be that the gas inhaled by the BITZER compressor allows a certain degree of superheat, but the ...
Visualizza i dettagli