Solution to High and Low Pressure Fault of Water Cooled Chiller
The method to eliminate the shortcomings of high and low pressure of water-cooled chiller has always been a key point and difficulty in the industry, so it is very important to master the solutions to the shortcomings of high and low pressure of water-cooled chiller. The reason can be preliminarily identified as poor water quality, and corresponding impurities (leaves, weeds, etc.) enter the water distribution hole, which affects the heat dissipation of the cooling water tower. Next, I will introduce the reasons and solutions for the high and low pressure disadvantages of a water-cooled chiller.

Causes and solutions of high and low pressure disadvantages of water-cooled chiller:
In the application of water-cooled chiller, we often encounter high and low pressure alarm of chiller! In terms of high pressure, it is generally poor heat dissipation, which will lead to poor cooling effect of the chiller. For a long time, high pressure will also lead to high current and burn out the compressor. Generally, there is no cold coal or cold coal leakage in the low pressure alarm. The compressor will also be damaged if it works at low pressure for a long time.
Generally, water-cooled chillers have high and low pressure gauges, which are divided into high pressure and low pressure. In addition, industrial chillers are roughly divided into air-cooled chillers and water-cooled chillers: at present, the surface plate of industrial chillers on the market is divided into computer board and manual control board. High pressure and low pressure of computer board are well separated, but generally, the high and low pressure alarm lights of manual control board chillers are together, so it is not so easy to distinguish.
Therefore, you should first know whether the chiller you are using is an air-cooled chiller or a water-cooled chiller, whether it is a computer board or a manual control board, whether it is a high-pressure alarm or a low-pressure alarm. For the high-pressure alarm of the air-cooled chiller, you need to clean the cooling network, and for the low-pressure alarm, you need to check whether the cold coal leaks or the pressure gauge has no pressure, The high pressure alarm of water-cooled chiller requires cleaning the condenser. Low pressure alarm also depends on whether the pressure gauge has no pressure, so it is necessary to check the leakage, make up the deficiency and add cold coal.
Raccomandazioni correlate
-
Expansion valve description of cooling water circulation machine for electric vehicle parts testing
956The demand for electric vehicle parts testing cooling water circulation machine in the testing of new energy vehicle battery industry is rising, so the choice is very important. Among them, the expansion valve is a more important accessory, and we...
Visualizza i dettagli -
Introduction to mixed solution of glycol chilling systems (glycol chillers)
876Glycol chillers are industrial refrigeration systems that use a type of antifreeze called glycol, mixed with water, to lower the freezing point in the application of the chilling system. Glycol is a class of organic compounds that belong to the ...
Visualizza i dettagli -
Installation method of heating and cooling temperature control system for automobile motor
1067In chemical and pharmaceutical, chemical laboratories, pilot plants and other industrial processes, the heating and cooling temperature control system is the most used equipment for temperature control in chemical manufacturing, so a highly dynami...
Visualizza i dettagli -
Air-cooled and water-cooled methods of cooling and heating circulators
1081The cooling heating circulator is controlled by high and low temperature during operation. After the user runs at high temperature and low temperature, it can be heated with heat transfer oil, which is water-cooled and air-cooled. 1. It belongs ...
Visualizza i dettagli