Selection of ultra-low temperature chiller supporting the glass reactor
In order to achieve an economical ultra-low temperature environment for glass reactors, many customers will not choose multi-stage compressor refrigeration equipment with more than two stages, but use liquid nitrogen. The cost of liquid nitrogen is low, and this refrigeration method is welcomed by some users, both in experiments and in production. However, due to the low boiling point of liquid nitrogen (minus 195.8°C), the latent heat is small and it is easy to evaporate. There are also big problems with using liquid nitrogen refrigerators safely.
In the storage, transportation and application of liquid nitrogen, it is necessary to have storage and application equipment with good thermal insulation performance. Most of the liquid nitrogen related equipment and pipeline fittings on the market adopt double-walled vacuum container structure. The key factor affecting the performance of this vacuum container and accessories is the vacuum degree of the interlayer. Moreover, the use of liquid nitrogen puts forward higher requirements on the reactor temperature control method, heat preservation measures, material properties, equipment sealing and pressure control, and environmental safety measures. Glass reactors cooled with liquid nitrogen must still retain the advantage of being transparent and visible during the reaction. Moreover, liquid nitrogen is a health hazard: skin contact with liquid nitrogen can cause frostbite. If the nitrogen produced by vaporization under normal pressure is excessive, the partial pressure of oxygen in the air will drop, causing hypoxia and suffocation. Guanya Refrigeration’s ultra-low temperature freezer adopts the single-machine cascade refrigeration process, and the low temperature can reach minus 150 degrees; it adopts the secondary supercooling technology, and the refrigeration is rapid.
Raccomandazioni correlate
-
LNEYA: Focus on temperature control TCU to build international advanced Chinese instruments
1040Wide temperature range: LNEYA's Chinese and production-grade multi-reactor refrigeration heating temperature control system (temperature control unit TCU) temperature range from -25 ° C to 200 ° C, of course, you can also customize other temperatu...
Visualizza i dettagli -
Precautions for use of minus 95 degrees cryogenic liquid bath cold trap
1042The minus 95 degree low temperature liquid bath cold trap (that is, the refrigerator that we often say) is a common refrigeration unit in refrigeration equipment. The rational use of the unit can not only avoid the failure of the unit, but also ma...
Visualizza i dettagli -
16. - 18. Giugno 2020 | L'Expo dei test automobilistici in Europa-LNEYA
1367L'Automotive Testing Expo Europe è una fiera per il collaudo, la valutazione e l'ingegneria della qualità nel settore automobilistico. È uno degli eventi più importanti del suo genere in Europa. La fiera presenta le tecnologie e i servizi più recenti per migliorare la qualità, la sicurezza...
Visualizza i dettagli -
How to solve the problem of returning oil in ultra-low temperature freezer?
1467The ultra-low temperature freezer will fail after a long period of use, and the user needs special attention when oil return occurs. In the ultra-low temperature freezer, the oil return is not smooth, which will cause a large amount of lubricating...
Visualizza i dettagli