Routine maintenance of tcu multi-reactor temperature control equipment

TCU multi-reactor temperature control equipment is widely used in research departments such as petroleum, chemical, electronic instruments, physics, chemistry, bioengineering, physical property testing and chemical analysis, colleges and universities, enterprise quality inspection and production departments to provide users with a liquid environment with controlled cold and hot, uniform and constant temperature when working.
1. Tcu multi-reactor temperature control equipment is a heating equipment that can control the temperature of the reaction material by heating the heat transfer oil in the jacket of the reactor to transfer heat energy to the material in the reactor indirectly.
2. The whole liquid circulation is a closed system. There is no absorption of water vapor at low temperature and no oil mist at high temperature. The heat transfer oil can work at a wide temperature; The same machine and the same heat conduction medium can realize continuous temperature rise and fall control.
3. Equipped with a heating and cooling integrated container, the heat exchange area is large, the heating and cooling rate is fast, and the demand for heat transfer oil is relatively small. It can realize continuous temperature rise and fall. Refrigeration heat exchanger adopts plate heat exchanger with high heat exchange efficiency and small floor area.
4. It has self-diagnosis function, refrigerator overload protection, high-voltage pressure switch, overload relay, thermal protection device and other reliable guarantee functions, fully ensuring reliable use;
5. In case of power failure, use dry compressed air regularly to clean the inside of the machine’s electric box and heat dissipation dust to avoid electrical failure caused by metal residues falling on the electrical components;
6. During normal use, use dry compressed air regularly to clean the metal residue and dust on the fan cover of the pump inside the machine to prevent the motor from radiating poorly after the fan cover is blocked, which may cause abnormal noise or jamming of the pump motor;
7. During long-term use, regularly maintain or replace other machine parts according to other requirements in the manual. In case of shutdown, regularly clean the filter at the oil return port of the machine to avoid over-temperature alarm and other faults caused by filter blockage; Customers can formulate effective maintenance plans according to the use of the machine and the site environment.
Raccomandazioni correlate
-
Precauzioni per il congelatore a bassissima temperatura
9981. Requisiti dell'ambiente dell'apparecchiatura: Per mantenere l'esterno del frigorifero criogenico pulito e ventilato, è necessario mantenere stabile la posizione orizzontale del frigorifero criogenico e assicurarsi che non ci siano oggetti in giro.2. Mana...
Visualizza i dettagli -
Istruzioni per la selezione dell'olio per il trasferimento di calore del congelatore 12hp
1133When choosing a 12hp freezer, users need to pay attention to the choice of heat transfer oil. For LNEYA, suitable heat transfer oil is very important. What should you pay attention to when choosing heat transfer oil? The 12hp freezer adopts a full...
Visualizza i dettagli -
How to check the air tightness of 40 screw freezer?
1206Air tightness is related to the cooling effect of the entire 40-screw freezer. Therefore, the manufacturer of 40-pin screw freezer of LushiA (LNEYA) recommends that users do 4 inspections, then how to check the work? This test is carried out on a ...
Visualizza i dettagli -
Battery test cooling device Chiller common configuration instructions
1268Under normal use, the battery test cooling device Chiller needs to be discovered in time when any part of the abnormality occurs. This requires a clear understanding of the basic configuration of the battery test cooling device Chiller. The batter...
Visualizza i dettagli