KRY 0℃~100℃ – LNEYA Air cooled chiller or Water cooled chiller https://www.lneya.com/it Industrial Chillers & Freezers Manufacturer, Dynamic Temperature Control Systems - LNEYA Fri, 23 Feb 2024 02:18:51 +0000 it-IT hourly 1 https://wordpress.org/?v=6.4.3 https://www.lneya.com/wp-content/uploads/2023/05/Lneya-logo-e1683777581854-150x137.png KRY 0℃~100℃ – LNEYA Air cooled chiller or Water cooled chiller https://www.lneya.com/it 32 32 KRY 0℃~+100℃(1&2) https://it.lneya.com/special-chiller/kry-2.html https://it.lneya.com/special-chiller/kry-2.html#respond Wed, 17 May 2023 08:02:32 +0000 https://www.lneya.com/special-chiller/kry-2.html
KRY 0℃~+100℃(1&2)
KRY 0℃~+100℃(1&2)
KRY 0℃~+100℃(1&2)
KRY 0℃~+100℃(1&2)
KRY 0℃~+100℃(1&2)

KRY 0℃~100℃ 1&2S

Normal temperature chiller for vehicle antifreeze test
  • Potenza di riscaldamento10kW~38kW
  • Capacità di raffreddamento7kW~60kW
  • Gamma di potenza17kW~65kW
  • Precisione della temperatura±0.5℃
  • Uscita di portata2~50 L/min
  • RefrigeranteR404A/R507C/R125/N40
  • Peso360KG~1700KG

Download dei dati del prodotto

  • manuale.pdf

Parametri Descrizione

Modello KRY-75/2S KRY-A15/2S KRY-A25W/2S KRY-A38W/2S KRY-A60W/2S
KRY-75W/2S KRY-A15W/2S
Temperatura. Intervallo 0℃~+100℃
Temp. control precision ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃
Feedback temp. Pt100 Pt100 Pt100 Pt100 Pt100
Temp. display 0.01k 0.01k 0.01k 0.01k 0.01k
Controllo di flusso/Gruppo 2~25 L/min 2~25 L/min 2~25L/min 5~50 L/min 5~50 L/min
Precisione del controllo di flusso/Gruppo ±0.2L ±0.2L ±0.2L ±0.2L ±0.2L
Numero di gruppi di uscita del fluido 2 Groups 2 Groups 2 Groups 2 Groups 2 Groups
pressure control/Group 0.2bar~2.5bar 0.2bar~2.5bar 0.2bar~2.5bar 0.2bar~2.5bar 0.2bar~2.5bar
flow pressure description The equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized)
Potenza di riscaldamento 10kW 10kW 15kW 25kW 38kW
capacità di raffreddamento 100℃ 10kW 15kW 25kW 38kW 60kW
20℃ 10kW 15kW 25kW 38kW 60kW
5℃ 7kW 11kW 18kW 27kW 42kW
compression Compressore a ruota Emerson Valley
expansion Danfoss  Thermal Expansion Valve/ Emerson Solenoid
oil distributor Emerson
Dry filter, Pressure Emerson/Danfoss
Evaporatore Scambiatore di calore a piastre
Ciriulating pump Magnetic pump
Frequency Delta
Flow, Pressure sensor German brand flowmeter, johnson Controls pressure
input, Display 5 inch color touch screen \ Siemens S7-1200 PLC controller
Comunicazione Protocollo Modbus RTU Interfaccia RS485, bus di comunicazione CAN opzionale, interfaccia Ethernet Protocollo TCP/IP
Protezione di sicurezza Con funzione di autodiagnosi; protezione da sovraccarico del frigorifero; pressostato di alta pressione, relè di sovraccarico, protezione termica
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
refrigerante R404A/R507C/R125/N40 All four refrigerants are available
Dimensioni del collegamento There are two groups of inlet and outlet,G3/4
Cooling water at 20C° 2600L/H 3200L/H 6000L/H 9000L/H 15000L/H
Condensatore (W) Scambiatore di calore a tubi Shenshi
Potenza 380V50HZ 17kW 20kW 31kW 43kW 65kW
Dimensioni cm 70*100*175 80*120*185 100*150*185 120*180*205 145*205*225
Peso 360KG 450kg 750 kg 1000kg 1700kg
Opzionale 220V 60HZ three phase    460V 60H three phase

Descrizione del prodotto

L'intervallo di temperatura è di -40℃~+100℃, che può essere esteso a +135℃ in base alla situazione reale, e la precisione del controllo della temperatura è di più o meno 0,5℃. L'apparecchiatura è in grado di controllare la portata e la pressione in modo indipendente mentre controlla la temperatura; per il controllo simultaneo sono necessarie diverse soluzioni personalizzate.

   Dotato di una potente pompa di circolazione che garantisce l'erogazione di liquidi altamente viscosi.
  Controllo della portata in uscita con regolazione a frequenza variabile o valvola di controllo proporzionale per ottenere una regolazione ad alta precisione del campo totale 5%~100%.



Temperatura di prova dei principali elementi di prova dell'elettronica del veicolo:


   Condizioni di prova IC per le locomotive: -40℃~125℃, vento, esposizione al sole, forti vibrazioni;
   Condizioni di prova del funzionamento del quadro strumenti: -40℃~85℃;
  Condizioni di prova del controllore del motore: temperatura di prova operativa: 40 ℃ ~ 110 ℃;
Posizionamento satellitare (GPS) Condizioni di prova: temperatura di prova di funzionamento ad alta temperatura: 85℃; temperatura di prova di funzionamento a bassa temperatura: -40℃;
  Vibrazione composta: -40℃~80℃;
  Ovviamente la soluzione migliore è che il centro di prova disponga di un sistema di simulazione della temperatura.

Fare clic sul messaggio online per richiedere i dettagli del prodotto
Send us a message about KRY 0℃ 1&2
Send us a message about KRY 0℃ 1&2
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Potreste essere interessati anche a questi prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/kry-2.html/feed 0
KRY 0℃~+100℃(1&3) https://it.lneya.com/special-chiller/kry-3.html https://it.lneya.com/special-chiller/kry-3.html#respond Wed, 17 May 2023 08:02:29 +0000 https://www.lneya.com/special-chiller/kry-3.html
KRY 0℃~+100℃(1&3)
KRY 0℃~+100℃(1&3)
KRY 0℃~+100℃(1&3)
KRY 0℃~+100℃(1&3)
KRY 0℃~+100℃(1&3)

KRY 0℃~100℃ 1&3S

Simulazione della temperatura di prova dell'antigelo del veicolo
  • Potenza di riscaldamento5,5kW~60kW
  • Capacità di raffreddamento11kW~60kW
  • Gamma di potenza22kW~68kW
  • Precisione della temperatura±0.5℃
  • Uscita di portata1~40 L/min
  • RefrigeranteR404A/R507C
  • Peso420KG~1700KG

Download dei dati del prodotto

KRY 0℃~100℃ 1&3S (3 sets of auxiliary temperature control, pressure/flow controlled separately)

Modello KRY-A15W/3S KRY-A25W/3S KRY-A38W/3S KRY-A60W/3S
KRY-A15/3S KRY-A25/3S
Temperatura. Intervallo 0℃~+100℃
Temp. control precision ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃
Feedback temp. Pt100 Pt100 Pt100 Pt100
Temp. display 0.01k 0.01k 0.01k 0.01k
Controllo di flusso/Gruppo 2~25 L/min 2~25 L/min 2~25 L/min 1~25 L/min
Precisione del controllo di flusso/Gruppo ±0.2L ±0.2L ±0.2L ±0.2L
Numero di gruppi di uscita del fluido 3 Groups 3 Groups 3 Groups 3 Groups
pressure control/Group 0.2bar~2.5bar 0.2bar~2.5bar 0.2bar~2.5bar 0.2bar~2.5bar
flow pressure description The equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized)
Potenza di riscaldamento 10kW 15kW 25kW 38kW
capacità di raffreddamento 100℃ 15kW 25kW 38kW 60kW
20℃ 15kW 25kW 38kW 60kW
5℃ 11kW 18kW 27kW 42kW
compression Compressore a ruota Emerson Valley
expansion Danfoss  Thermal Expansion Valve/ Emerson Solenoid
oil distributor Emerson
Dry filter, Pressure Danfoss
Evaporatore Scambiatore di calore a piastre
Ciriulating pump Nangfang centrifugal pump can be selected with imported brand magnetic pump
Frequency Delta
Flow, Pressure sensor German brand flowmeter, johnson Controls pressure
input, Display Controllore PLC con touch screen a colori da 7 pollici
Comunicazione Protocollo Modbus RTU Interfaccia RS485, bus di comunicazione CAN opzionale, interfaccia Ethernet Protocollo TCP/IP
Protezione di sicurezza Con funzione di autodiagnosi; protezione da sovraccarico del frigorifero; pressostato di alta pressione, relè di sovraccarico, protezione termica
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
refrigerante R404A/R507C/R125/N40 All four refrigerants are available
Dimensioni del collegamento There are three groups of inlet and outlet,ZG3/4
Cooling water at 20C° 3200L/H 6000L/H 9000L/H 15000L/H
Condensatore (W) Scambiatore di calore a tubi Shenshi
Potenza 380V50HZ 22kW 33kW 45kW 68kW
Dimensioni cm 80*120*185 100*150*185 100*150*185 100*150*185
Peso 420kg 750 kg 1000kg 1700kg
Opzionale 220V 60HZ three phase    460V 60H three phase
Opzionale La dimensione della tubazione di circolazione esterna è DN15 o DN20, non strozzare, il che aumenterà il carico della pompa di circolazione,
Il tubo deve essere isolato, e adottare tubi isolanti in gomma e plastica in grado di sopportare temperature elevate.
Opzionale When the temperature is lower than the normal temperature, the refrigeration system adopts the refrigeration PID to adjust the cooling capacity, and does not adopt the heating countermeasures, so as to achieve the purpose of energy saving

Descrizione del prodotto



Temperatura di prova dei principali elementi di prova dell'elettronica del veicolo:


   Condizioni di prova IC per le locomotive: -40℃~125℃, vento, esposizione al sole, forti vibrazioni;
   Condizioni di prova del funzionamento del quadro strumenti: -40℃~85℃;
  Condizioni di prova del controllore del motore: temperatura di prova operativa: 40 ℃ ~ 110 ℃;
Posizionamento satellitare (GPS) Condizioni di prova: temperatura di prova di funzionamento ad alta temperatura: 85℃; temperatura di prova di funzionamento a bassa temperatura: -40℃;
  Vibrazione composta: -40℃~80℃;
  Ovviamente la soluzione migliore è che il centro di prova disponga di un sistema di simulazione della temperatura.

Fare clic sul messaggio online per richiedere i dettagli del prodotto
Inviaci un messaggio riguardo alla serie KRY
Inviaci un messaggio riguardo alla serie KRY
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Potreste essere interessati anche a questi prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/kry-3.html/feed 0
KRY 0℃~+100℃(1&6) https://it.lneya.com/special-chiller/kry-6.html https://it.lneya.com/special-chiller/kry-6.html#respond Wed, 17 May 2023 08:02:26 +0000 https://www.lneya.com/special-chiller/kry-6.html
KRY 0℃~+100℃(1&6)
KRY 0℃~+100℃(1&6)
KRY 0℃~+100℃(1&6)
KRY 0℃~+100℃(1&6)
KRY 0℃~+100℃(1&6)

KRY 0℃~100℃ 1&6S

Normal temperature chiller for vehicle antifreeze test temperature simulation
  • Potenza di riscaldamento15kW~38kW
  • Capacità di raffreddamento18kW~60kW
  • Gamma di potenza38kW~82kW
  • Precisione della temperatura±0.5℃
  • Uscita di portata2~50 L/min
  • RefrigeranteR404A/R507C/R125/N40
  • Peso900KG~1950KG

Download dei dati del prodotto

KRY 0℃~100℃ 1&6S (6 sets of auxiliary temperature control, pressure and flow controlled separately)

Modello KRY-A25W/6S KRY-A38W/6S KRY-A60W/6S
Temperatura. Intervallo 0℃~+100℃
Temp. control precision ±0.5℃ ±0.5℃ ±0.5℃
Feedback temp. Pt100 Pt100 Pt100
Temp. display 0.01k 0.01k 0.01k
Controllo di flusso/Gruppo 2~20 L/min 2~20 L/min 2~20 L/min
Precisione del controllo di flusso/Gruppo ±0.2L ±0.2L ±0.2L
Numero di gruppi di uscita del fluido 6 Groups 6 Groups 6 Groups
pressure control/Group 0.2bar~2.5bar 0.2bar~2.5bar 0.2bar~2.5bar
flow pressure description The equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized)
Potenza di riscaldamento 15kW 25kW 38kW
capacità di raffreddamento 100℃ 25kW 38kW 60kW
20℃ 25kW 38kW 60kW
5℃ 18kW 27kW 42kW
compression Compressore a ruota Emerson Valley
expansion Electronic Expansion Valve
oil distributor Emerson
Dry filter, Pressure Danfoss
Evaporatore Scambiatore di calore a piastre
Ciriulating pump Nangfang centrifugal pump can be selected with imported brand magnetic pump
Frequency Delta
Flow, Pressure sensor German brand flowmeter, johnson Controls pressure
input, Display Controllore PLC con touch screen a colori da 5 pollici
Comunicazione Protocollo Modbus RTU Interfaccia RS485, bus di comunicazione CAN opzionale, interfaccia Ethernet Protocollo TCP/IP
Protezione di sicurezza Con funzione di autodiagnosi; protezione da sovraccarico del frigorifero; pressostato di alta pressione, relè di sovraccarico, protezione termica
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
is it a fully closed system The whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature in operation, and the thermal conduction medium will be automatically supplemented at low temperature.
refrigerante R404A/R507C/R125/N40 Tutti e quattro i refrigeranti sono disponibili
Dimensioni del collegamento Ci sono sei gruppi di ingressi e uscite,ZG3/4
Cooling water at 20C° 6000L/H 9000L/H 15000L/H
Condensatore (W) Scambiatore di calore a tubi Shenshi
Potenza 380V50HZ 38kW 55kW 82kW
Dimensioni cm 200*145*205 200*145*205 200*145*205
Peso 900 kg 1200kg 1950kg
Opzionale 220V 60HZ three phase    460V 60H three phase
Opzionale Estensione a -40~+135℃
Opzionale La dimensione della tubazione di circolazione esterna è DN15 o DN20, non strozzare, il che aumenterà il carico della pompa di circolazione,
Il tubo deve essere isolato, e adottare tubi isolanti in gomma e plastica in grado di sopportare temperature elevate.
Opzionale When the temperature is lower than the normal temperature, the refrigeration system adopts the refrigeration PID to adjust the cooling capacity, and does not adopt the heating countermeasures, so as to achieve the purpose of energy saving

Descrizione del prodotto



Principio di funzionamento

Simulazione della temperatura per il test di qualità del veicolo: test di durata della batteria, banco di prova dell'iniettore/motore del carburante, test dell'airbag, banco di prova dei componenti, ecc. Può simulare le condizioni ambientali esterne nella camera climatica o sostituire il sistema interno, creando le condizioni di temperatura reali necessarie per il banco di prova.

Temperatura di prova dei principali elementi di prova dell'elettronica del veicolo:


   Condizioni di prova IC per le locomotive: -40℃~125℃, vento, esposizione al sole, forti vibrazioni;
   Condizioni di prova del funzionamento del quadro strumenti: -40℃~85℃;
  Condizioni di prova del controllore del motore: temperatura di prova operativa: 40 ℃ ~ 110 ℃;
Posizionamento satellitare (GPS) Condizioni di prova: temperatura di prova di funzionamento ad alta temperatura: 85℃; temperatura di prova di funzionamento a bassa temperatura: -40℃;
  Vibrazione composta: -40℃~80℃;
  Ovviamente la soluzione migliore è che il centro di prova disponga di un sistema di simulazione della temperatura.

Fare clic sul messaggio online per richiedere i dettagli del prodotto
Richiesta di preventivo e informazioni sul programma
Richiesta di preventivo e informazioni sul programma
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Potreste essere interessati anche a questi prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/kry-6.html/feed 0
KRY 0℃~+100℃ (1&1) https://it.lneya.com/special-chiller/kry-0.html https://it.lneya.com/special-chiller/kry-0.html#respond Wed, 17 May 2023 07:51:36 +0000 https://www.lneya.com/special-chiller/kry-0.html
KRY 0℃~+100℃ (1&1)
KRY 0℃~+100℃ (1&1)
KRY 0℃~+100℃ (1&1)
KRY 0℃~+100℃ (1&1)
KRY 0℃~+100℃ (1&1)

KRY 0℃~100℃ 1&1

Normal temperature chiller for Vehicle antifreeze test
  • Potenza di riscaldamento2,5kW~38kW
  • Capacità di raffreddamento1,8kW~60kW
  • Gamma di potenza4.5kW~61kW
  • Precisione della temperatura±0.5℃
  • Uscita di portata2~50 L/min
  • RefrigeranteR404A/R507C
  • Peso220KG~1300KG

Download dei dati del prodotto

Fare clic sul messaggio online per richiedere i dettagli del prodotto
Inviaci un messaggio riguardo alla serie KRY
Inviaci un messaggio riguardo alla serie KRY
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

L'intervallo di temperatura è di -40℃~+100℃, che può essere esteso a +135℃ in base alla situazione reale, e la precisione del controllo della temperatura è di più o meno 0,5℃. L'apparecchiatura è in grado di controllare la portata e la pressione in modo indipendente mentre controlla la temperatura; per il controllo simultaneo sono necessarie diverse soluzioni personalizzate.


   L'oggetto testato è collegato a un adattatore della piattaforma di test.
   L'interno del pezzo è stato raffreddato e riscaldato da una soluzione acquosa di glicole etilenico.
  Il componente di prova deve seguire un profilo di temperatura specifico e registrare le variazioni di temperatura.
   Quando si esegue un test di tolleranza, di solito è necessario un ciclo infinito.

   Dotato di una potente pompa di circolazione che garantisce l'erogazione di liquidi altamente viscosi.
  Controllo della portata in uscita con regolazione a frequenza variabile o valvola di controllo proporzionale per ottenere una regolazione ad alta precisione del campo totale 5%~100%.

Parametri dettagliati

Modello KRY-25 KRY-55 KRY-75 KRY-A10 KRY-A15 KRY-A25 KRY-A38W KRY-A60W
KRY-A15W KRY-A25W
Temperatura. Intervallo 0℃~+100℃
Temp. control precision ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃
Feedback temp. Pt100 Pt100 Pt100 Pt100 Pt100 Pt100 Pt100 Pt100
Temp. display 0.01k 0.01k 0.01k 0.01k 0.01k 0.01k 0.01k 0.01k
Uscita di portata 2~20 L/min 2~25 L/min 2~25 L/min 2~25 L/min 2~25 L/min 2~25 L/min 5~50 L/min 5~50 L/min
Precisione della portata ±0,2 L/min ±0,2 L/min ±0,2 L/min ±0,2 L/min ±0,2 L/min ±0,2 L/min ±0,2 L/min ±0,2 L/min
Pressure display Adopt the Jeffron pressure sensor, the touch screen display the pressure, can carry on the pressure control adjustment.
Potenza di riscaldamento 2,5kW 5,5kW 7,5kW 10kW 10kW 15kW 25kW 38kW
  Optional 15kW Optional 25kW Optional 38kW Optional 60kW
capacità di raffreddamento 100℃ 2,5kW 5,5kW 7,5kW 10kW 15kW 25kW 38kW 60kW
  20℃ 2,5kW 5,5kW 7,5kW 10kW 15kW 25kW 38kW 60kW
  5℃ 1,8kW 3,8kW 5.2kW 7kW 11kW 18kW 27kW 42kW
compression HITACHI Compressore a ruota Emerson Valley
expansion Danfoss  Thermal Expansion Valve/ Emerson Solenoid
oil distributor Emerson
Dry filter, Pressure Emerson/Danfoss
Evaporatore Scambiatore di calore a piastre
input, Display 7 inch color touch screen \ PLC controller
program edit 5 programs can be prepared, each program can be prepared 20 steps
Comunicazione CAN communications bus
Protezione di sicurezza Con funzione di autodiagnosi; protezione da sovraccarico del frigorifero; pressostato di alta pressione, relè di sovraccarico, protezione termica
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
is it a fully closed system The whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature in operation, and the thermal conduction medium will be automatically supplemented at low temperature.
refrigerante R404A/ R507C  export adopt R448A
Flow sensor German brand flowmeter
Dimensioni del collegamento ZG3/4 ZG3/4 ZG3/4 ZG3/4 ZG3/4 ZG3/4 ZG3/4 ZG3/4
Cooling water at 20C°         3200L/H 6000L/H 9000L/H 15000L/H
Condensatore (W) Scambiatore di calore a tubi (Parigi/Shenshi)
Condensatore(A) Scambiatore di calore alettato in alluminio a tubi di rame (vento ascendente)
Potenza 380V50HZ 4.5kW220V 8,5kW 11,5kW 16kW 18kW 28kW 40kW 61kW
Dimensioni cm 40*70*160 55*100*175 55*100*175 70*100*175 80*120*185 100*150*185 100*150*185 100*150*185
Peso   250 kg 280kg 320 kg 360 kg 620kg 890kg 1300KG
Opzionale 220V 60HZ three phase    460V 60HZ three phase
Opzionale Controllo di maggiore precisione di temperatura, flusso e pressione
Opzionale Sistema di riempimento automatico dell'antigelo
Opzionale Automatic liquid recovery system

Descrizione del prodotto



Principio di funzionamento

Simulazione della temperatura per il test di qualità del veicolo: test di durata della batteria, banco di prova dell'iniettore/motore del carburante, test dell'airbag, banco di prova dei componenti, ecc. Può simulare le condizioni ambientali esterne nella camera climatica o sostituire il sistema interno, creando le condizioni di temperatura reali necessarie per il banco di prova.

Potreste essere interessati anche a questi prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/kry-0.html/feed 0